User-recorded edid information, E for, Pre-programmed edid information – Extron Electronics RGB 203 Rxi User Guide User Manual
Page 20: Edid information from the local, Monitor output

Using user-recorded EDID information
Position 0 uses the EDID information that has been saved by the user (see “
” on the page 12). To use this information:
1.
Connect the RGB 203 Rxi to the source. Do not switch on the source device yet.
2.
Set the rotary switch to 0.
3.
Power on the source device.
NOTE: By default, setting 0 on the rotary switch has no EDID information saved to it.
The user must save EDID to this location before it can be used.
Using pre-programmed EDID information
Positions 1 to E select from among 14 commonly used output resolutions that have been
preset at the factory. Position 2 (1024x768) is the default setting, to ensure the unit works as
shipped. See
for the resolution associated with each position on the
dial. To use one of the pre-defined EDID files:
1.
Connect the RGB 203 Rxi to the source. Do not switch on the source device at this time.
2.
Set the first DIP switch (
f
) to the required frequency (50 or 60 Hz).
3.
Set the rotary switch to the required value (see the
).
4.
Power on the source device.
Using pass-through EDID information from the local monitor
Position F passes through EDID information from a local monitor. To use this information:
1.
Turn the EDID rotary switch to position F (see
g
on the previous page).
2.
Connect the display device to the local monitor output connector (see
on page 3) and power on the display.
3.
Power on the source device.
NOTE: EDID information must be available to the source device as it boots up. Before
booting the source device, make sure the RGB 203 Rxi and the local monitor (if
required) are powered on and the rotary dial is set to the correct value.
RGB 203 Rxi • Operation