MLC 104 Series MediaLink Controllers • Hardware Setup

Hardware Setup

MLC 104 Series MediaLink Controllers • Hardware Setup

2-3

2-2

This chapter describes right, left, and front panel features, basic

front panel operation, and how to connect cables to the

MLC 104 series controller.

Rght Sde Panel Features and Connectons

+V

G

SCP

+12V OUT

PWR SNS

GROUND

GROUND

GROUND

GROUND

GROUND

Tx
Rx

HOST/

CONFI

G

LAN

PRESS

TAB
WITH

TWEEKER

TO

REMO

VE

A

B

A B

E

MLS

PWR

RS-232 12V

SCP

COMM

DISPLA

Y

RS-232/IR

Tx/IR

Rx

Tx

Rx

+12V IN

3

2

1

6

Right Side

MLC 104 Series
Right Side Panel

4

5

a

Right panel, Host/Config port — For MLC configuration and

control, connect to the 3-pin captive screw.
This port has the following RS-232 protocol:
• 38400 baud

• 1 stop bit
• no parity
• 8 data bits
• no flow control

b

Display RS-232 /IR port — This port is configurable for

bidirectional RS-232 or infrared signal output control.
From this port, commands sent from a driver or user-defined

command strings (entered via the Global Configurator) can be

sent to the display device.
For bidirectional RS-232 communication, the transmit, ground,

and receive pins must be wired at both the controller and the

projector connectors, as shown on the following page.

Projector

Panel

MLC 104 Series

Right Side Panel

DISPLAY

RS-232/IR

Tx/IR

Rx

GR

OUND

PWR SNS

GR

OUND

+12V OUT

Ground ( )

Receive (Rx)

Transmit (Tx)

Ground ( )

Receive (Rx)

Transmit (Tx)

Bidirectional

N

Each projector or display may require different wiring. For

details, refer to the manual that came with your projector.

c

SCP Comm port — The SCP 104 replicates the MLC’s front

panel controls. You can connect up to two Extron SCP 104

control pads to this port to allow remote control of the MLC 104

controller.

SCPs can be daisy chained. Extron recommends the

Comm-Link (CTL and CTLP) cable for these connections.

+V

G

SC

P

+1

2V

O

UT

GR

OU

ND

GR

OU

ND

A B

A B E

MLS PWR

RS-232 12V

SCP

COMM

Tx

R

x

+1

2V

IN

MLC 104 Series

Right Side Panel

E

B

A

SCP communication (IR)

Ground ( )

+12 VDC

Maximum =
2 SCPs
Per System

Ground ( ) & Drain Wire

E
C

B

A

SCP Communication
Control Module Communication

+12 VDC

= White

= Black & Drain Wire

= Violet

= Red

SCP 104

CONFIG

DISPLAY

VOLUME

SCP 104

ON

PC

VCR

DVD

OFF

1

2

3

4

200' (61 m) max.

to Last Device

Extron CTLP Cable Color Code:

An MLC 104 series controller daisy chained to a
SCP 104

N

The maximum distance allowed between an MLC

controller and a SCP 104 is 200’ (61 m).