MLC 104 Series MediaLink Controllers • Software Setup

Software Setup, cont’d

3-20

MLC 104 Series MediaLink Controllers • Software Setup

3-21

Display lamp hour e-mail notification

9

.

Click Done. The dialog box closes.

Step 9: Create a Dsplay Dsconnecton

E-mal (IP model only)

To set a display disconnected e-mail alert, do the following:
1

.

Click the Monitor tab in the Global Configurator window.

2

.

Click the Add Monitor button below the Monitored

Conditions

window. The Monitored Conditions Wizard

window appears.

3

.

Enter a name (enter Disconnected) in the Enter Monitored

Condition Name

field area. The label now appears in the

left pane.

4

.

Click Next to specify a condition.

5

.

Select the desired equipment (for our purposes, choose the

Epson PowerLite 7700p

) from the Subject Port window

and Connection Status: Disconnected from Available

Options

.

6

.

Click Apply Condition, then click Next.

7

.

Click Next again to add an e-mail notification.

8

.

Highlight the appropriate e-mail message (Disconnect

Notification

) and contacts (e-mail recipient), and click

Apply Email/Contacts

.

9

.

Click Done. The dialog box closes.

Step 10: Buld and Upload a Configuraton

The Global Configurator project file contains all the

configuration data (port assignments, product/device locations,

scheduling data, etc.) you have created in Global Configurator.

This is the data used to build the project's GlobalViewer Web

pages for the MLC 104 IP.

Buldng a configuraton

To build a configuration, do the following:
1

.

Click the GlobalViewer tab at the left pane window to open

GlobalViewer Designer.

2

.

Confirm that all configured products have been given a

location. If not, drag each product to the desired location

or create new ones.

3.

Save your project file. If a project file has not been

saved, GC prompts you to do so before building the

configuration.

4

.

From the Build menu, choose Build All Configurations or
Build Changed Configurations

.

The Build menu

An activity bar appears, indicating that the build is

progressing. The Upload Manager dialog appears when

the build is complete.