MLC 104 Series MediaLink Controllers • Software Setup
Software Setup, cont’d
3-18
MLC 104 Series MediaLink Controllers • Software Setup
3-19
Step 8: Create a Dsplay Lamp Hour Warnng
E-mal (IP model only)
Global Configurator’s monitoring feature enables you to
configure a MLC 104 IP controller to monitor many parameters
of the connected display devices. For example, a monitor alert
can warn the school administrator if a display lamp hour limit
is close to expiration, or if a display is inexplicably disconnected
from the MLC 104 IP controller.
To set a display lamp hour warning e-mail, do the following:
1
.
Click the Monitor tab in the Global Configurator window.
2
.
Click the Add Monitor button below the Monitored
Conditions
dialog. The Monitored Conditions Wizard
dialog appears.
3
.
Enter a name (e.g., Lamp hour) in the Enter Monitored
Condition Name
field area. The label now appears in the
left pane.
4
.
Click the Next button to specify a condition. This takes
you to the actions page, where you can specify the action.
Monitored Conditions Wizard dialog
5
.
In the Subject Port window, select the display
(choose Epson PowerLite 7700p) for which the lamp hour
warning is to be set. A list of monitoring options appears
under the Available Options window.
6
.
Set the lamp hour limit by doing the following:
a
. Choose Lamp Usage Time (hours): Value under the
Available Options
window.
b
. Enter a value (e.g., 800) in the Lamp Usage Time
(hours)
box.
c
. Click Apply Condition for each condition assigned.
d
. Click Next.
7
.
Click Next again to add an e-mail notification.
8
.
Click on the appropriate e-mail message and contacts,
then click Apply Email/Contacts.