Software configuration and control, cont’d – Extron Electronics MGP 462D User Manual
Page 62
Software Configuration and Control, cont’d
MGP 462 • Software Configuration and Control
4-14
Command/r
esponse table for SIS commands (continued)
Command
ASCII Command
Response
Additional description
(host to pr
ocessor)
(processor to host)
Total pixels, continued
V
iew total pixels setting
X5
5
*
11
#
X7
4
Show the current total pixels setting for input
X5
5
.
Active pixels
Set active pixels to a specific value
X5
5
*
X7
4
*
1
2#
Apx
X5
5
*
X7
4
Set active pixels value for input
X5
5
to
X7
4
.
Incr
ement active pixels value
X5
5
+
12#
Apx
X5
5
*
X7
4
Select the next higher active pixels value after
X7
4
.
Decr
ement active pixels value
X5
5
-
1
2#
Apx
X5
5
*
X7
4
Select the next lower active pixels value
before
X7
4
.
V
iew active pixels setting
X5
5
*
12#
X7
4
Show the current active pixels setting for
input
X5
5
.
Active lines
Set active lines to a specific value
X5
5
*
X7
4
*
1
3#
Aln
X5
5
*
X7
4
Set the active lines value for input
X5
5
to
X7
4
.
Incr
ement active lines value
X5
5
+
13#
Aln
X5
5
*
X7
4
Select the next higher active lines value.
Decr
ement active lines value
X5
5
-
1
3#
Aln
X5
5
*
X7
4
Select the next lower active lines value.
V
iew active lines setting
X5
5
*
13#
X7
4
Show the current active lines setting for input
X5
5
.
Scaler output r
esolution and scan rate
Set the output r
esolution and scan rate
X6
3
*
X7
2
=
Rte
X6
3
*
X7
2
Set the scaler output resolution to
X6
3
and
the scan rate to
X7
2
.
V
iew the output settings
=
Rte
X6
3
*
X7
2
Show the current output r
esolution and scan
rate settings.
Test Patter
n
Select test pattern
X5
9
J
T
st
X5
9
Select test pattern
X5
9
.
V
iew test pattern
J
X5
9
Show the current test pattern setting.
F
reeze
Enable
X5
7
* 1F
X5
7
Frz1
F
reeze the video image.
Disable
X5
7
* 0F
X5
7
Frz0
Unfreeze the
video image.
V
iew status
X5
7
F
X5
6
Show the freeze status.