Installation, cont’d, Reset button and led, Configuring the lan port – Extron Electronics MGP 462D User Manual
Page 20
Installation, cont’d
MGP 462 • Installation
2-6
Clip Down
1
1&2 3&6 4&5
7&8
2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
RJ-45
Connector
Twisted
Pairs
Straight-through Cable
(for connection to a switch, hub, or router)
End 1
End 2
Pin
Wire Color
Pin
Wire Color
1
white-orange 1 white-orange
2
orange 2
orange
3
white-green
3
white-green
4
blue 4
blue
5
white-blue 5
white-blue
6
green
6
green
7
white-brown
7
white-brown
8
brown
8
brown
Crossover Cable
(for direct connection to a PC)
End 1
End 2
Pin
Wire Color
Pin
Wire Color
1
white-orange 1 white-green
2
orange 2
green
3
white-green
3
white-orange
4
blue 4
blue
5
white-blue 5
white-blue
6
green
6
orange
7
white-brown
7
white-brown
8
brown
8
brown
Pin assignments for LAN connector and cables
Configuring the LAN port
You also need to configure the LAN port before using it. This is done with SIS
commands. See Command/Response table for IP control port commands in chapter 4 for
information on these commands.
The LAN port defaults are:
Processor IP address:
192.168.254.254
Gateway IP address:
0.0.0.0
Subnet mask:
255.255.0.0
DHCP:
off
Reset button and LED
6
Reset button and LED
— Pressing this recessed button causes certain IP
functions and Ethernet connection settings to be reset to the factory defaults.
The green LED above the button blinks a varying number of times to indicate
which reset mode has been entered. See Resetting the unit in chapter 3,
Operations, for information on reset modes.