Exiting the menu system, Resetting – Extron Electronics FOX 3G DVC User Guide User Manual
Page 23
![background image](/manuals/311732/23/background.png)
FOX 3G DVC • Operation
17
Alt Pixels
X-Hatch 4x4
Grayscale
Color Bars
Crop
1.78 Aspect
1.85 Aspect
2.35 Aspect
1.33 Aspect
Figure 19.
FOX 3G DVC Test Patterns
Int. Temp. screen
The Int. Temp. screen shows the current internal temperature of the DVC unit in degrees
Fahrenheit and Celsius. This is an information-only screen; no adjustments can be made
from it.
Exiting the Menu System
To exit the menu system, press the Menu button repeatedly until the
EXIT
MENU
PRESS
NEXT
screen appears. Press the Next button to return to the default cycle.
Alternatively, wait until the menu system times out and the default cycle resumes
(approximately 30 seconds).
Resetting
You can perform the following types of reset on the FOX 3G DVC:
•
Firmware and settings: To reset the FOX 3G DVC to its factory-installed firmware
version, press the front panel Menu button while connecting power to the unit. Perform
this reset if compatibility issues arise with an updated firmware version.
•
Settings only: To reset the unit to factory default settings, press and hold the Next
button while applying power to the unit. While the reset is in progress, the LCD screen
displays
SYSTEM
RESET
. When the reset is complete, the LCD screen displays
EXTRON
FOX3G
DVC
MM
(or
SM
), and the default cycle starts.
-or-
Enter the
ZXXX
Configuration and Control” section).