beautypg.com

Exiting the menu system, Resetting – Extron Electronics FOX 3G DVC User Guide User Manual

Page 23

background image

FOX 3G DVC • Operation

17

Alt Pixels

X-Hatch 4x4

Grayscale

Color Bars

Crop

1.78 Aspect

1.85 Aspect

2.35 Aspect

1.33 Aspect

Figure 19.

FOX 3G DVC Test Patterns

Int. Temp. screen

The Int. Temp. screen shows the current internal temperature of the DVC unit in degrees
Fahrenheit and Celsius. This is an information-only screen; no adjustments can be made
from it.

Exiting the Menu System

To exit the menu system, press the Menu button repeatedly until the

EXIT

MENU

PRESS

NEXT

screen appears. Press the Next button to return to the default cycle.
Alternatively, wait until the menu system times out and the default cycle resumes
(approximately 30 seconds).

Resetting

You can perform the following types of reset on the FOX 3G DVC:

Firmware and settings: To reset the FOX 3G DVC to its factory-installed firmware
version, press the front panel Menu button while connecting power to the unit. Perform
this reset if compatibility issues arise with an updated firmware version.

Settings only: To reset the unit to factory default settings, press and hold the Next
button while applying power to the unit. While the reset is in progress, the LCD screen
displays

SYSTEM

RESET

. When the reset is complete, the LCD screen displays

EXTRON

FOX3G

DVC

MM

(or

SM

), and the default cycle starts.

-or-
Enter the

ZXXX

SIS command (see the

Resetting command

in the “Remote

Configuration and Control” section).