beautypg.com

Powering on, Default cycle, Default cycle — special conditions – Extron Electronics FOX 3G DVC User Guide User Manual

Page 17: Default cycle default cycle — special conditions

background image

FOX 3G DVC • Operation

11

Powering On

Apply power by connecting the provided IEC power cord to the rear panel power connector
on the DVC. Connect the DVC to an AC power source.

NOTE: Audio and video mute settings are not retained when power is cycled to the

DVC.

Default Cycle

When power is applied, the LCD screen displays the Extron S

3

logo. After approximately 10

seconds, the screen displays

EXTRON

FOX3G

DVC

MM or SM. The unit part number and current

firmware version are displayed after approximately another 5 seconds. After those screens,
the default cycle begins, in which the LCD screen alternates every 5 seconds between the
input signal type and data rate, and the input resolution and refresh rate. The default cycle
continues while the menu system is not in use.
The flow diagram below shows the order in which the screens appear at power-up and
during the default cycle.

60-1034-01

F/W V1.00

5 sec.

5 sec.

EXTRON

FOX3G DVC MM

5 sec.

5 sec.

Power

On

10 sec.

INPUT

HDSDI 1.485G

INPUT

720p @59.94Hz

Default Cycle

Figure 10.

Power-up and Normal Default Cycle Example

Default Cycle — Special Conditions

The default cycle changes when the following conditions exist:

No input connected — A single screen is displayed, indicating that there is no input
signal.

INPUT

NO SIGNAL!

Figure 11.