Drop-in Installations
For installations with limited under-table access, the retractors must be installed before
dropping the enclosure into the table. All drop-in installations must be mounted vertically or
using angular mounting.
1.
For
retrofit installations, remove the Cable Cubby enclosure from the furniture.
For
new installations follow the Cable Cubby enclosure preparation instructions but
do not mount the enclosure.
2.
Install the retraction system in the enclosure following the installation instructions (see
CC 300, CC 600, CC 800, TLE, TLP Installation
NOTE: Connect all cables before lowering the enclosure into the cutout.
3.
Once the retraction system is installed, lower the
enclosure and retraction system into the cutout ensuring
that kinking or bending of the cables is prevented.
If the bottom of the retractors will not be accessible,
connect the pigtails before lowering the system.
4.
After the enclosure has been dropped into the opening,
lift it just enough to allow the two screw clamps to be
installed.
NOTE: In drop-in type installations, it is not
possible to adjust the screw clamps for an
exact fit and will take some trial and error
to adjust it for the tightest fit.