Cable Retraction System • Before Getting Started
9
Prepare the Cable Cubby Enclosure
DANGER: SEVERE ELECTRICAL SHOCK. Remove all power from the Cable
Cubby enclosure before beginning a retraction system installation.
All Installations
By now you should be certain the retraction system has adequate under-table clearance
for installation and that proper legroom will be provided to avoid accidental contact with the
system. You should have the required accessories for mounting the retraction system along
with the necessary AAPs and AAP brackets to reconfigure the enclosure.
The retraction system requires two adjacent AAP spaces and must be installed on one side
of the enclosure or the other with the cable release buttons against the enclosure side walls
(see figure 8). Filler modules, when used, take up the same space as one retractor. Where
the retraction system is installed in the enclosure is based on under-table clearance, the
mounting orientation of the retractors, and operation preferences.
Install or reconfigure the power module and AAP modules and brackets before beginning
the installation of the retraction system.
Retrofit Installations
Prepare the AAP spaces for the retraction system ensuring sufficient under-table clearance
for the retraction system.
Relocate, remove, or replace existing AAPs and reconfigure associated AAP brackets to
make room for the retraction system.
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
USP HUB4 AAP
AC
TIVITY
100-240V/ 5AMAX
Check for adequate cable
clearance inside the
Cable Cubby enclosure.
Retractors take
two AAP spaces.
Filler modules
(part #
70-678-08)
take up the same
space as one retractor.
CC 800 shown
The retraction system must be mounted on either
side of the enclosure with the cable release buttons
against the enclosure side walls.
Figure 8.
Retraction System AAP locations