Prepare the retractors, Horizontal or angular mounting, Angular mounting – Extron Electronics Cable Retraction System User Guide User Manual
Page 16: Horizontal or angular mounting: angular mounting
![background image](/manuals/311629/16/background.png)
Cable Retraction System • Before Getting Started
10
Prepare the Retractors
Each retractor is delivered ready to mount vertically. No further modifications are required.
See
CC 300, CC 600, CC 800, TLE, TLP Installation
on page 14 for vertical installation
details.
Horizontal or Angular Mounting:
To mount the retractors horizontally or at an angle, remove the two enclosure screws
from the retractor (see figure 9).
For horizontal mounting proceed to the
section
beginning on page 11.
For angular mounting, see below.
Remove two enclosure screws
(front and back) from this position
for horizontal or angular mounting.
Install two enclosure screws
(front and back) in angular
mounting location.
1
2
Cable Stop Assembly
Enclosure
Move cable stop assembly
upward until the angular
mounting hole is visible.
Figure 9.
Remove Enclosure Screws (Horizontal or Angular Mounting Only)
Angular Mounting:
1.
To prepare an XL retractor for angular mounting move the cable stop assembly upward
as shown until the mounting hole is visible.
Remove two enclosure screws
(front and back) from this position
for horizontal or angular mounting.
Install two enclosure screws
(front and back) in angular
mounting location.
1
2
Cable Stop Assembly
Enclosure
Move cable stop assembly
upward until the angular
mounting hole is visible.
Figure 10.
Install Angular Mounting Enclosure Screws
2.
Reinstall the two screws removed in the preparation above.
NOTE: For Cable Cubby 200 installations, mount the retractor onto the CC 200