Command and Response Table for IP- and SNMP-Specific SIS Commands

Symbol definitions

X4)

= Matrix name

(Up to 24 alphanumeric characters)

NOTE: The HTML language reserves certain characters for specific functions (see

Special Characters

on page 70).

X4!

= Default name

Matrix 3200 — FOX-4G-Matrix-3- + last 3 pairs of MAC address
Matrix 7200 — FOX-4G-Matrix-7- + last 3 pairs of MAC address

X4@

= Time and date (for set)

In the format: MM/DD/YY•HH:MM:SS where:
MM = month: 01 (January) through 12 (December)
DD = day: 01 through 31
YY = year: 00 through 99
HH = hour: 00 through 23
MM = minutes: 00 through 59
SS = seconds: 00 through 59

X4#

= Time and date (for read)

In the format: Day,•DD•Mmm•YYYY•HH:MM:SS where:
Day = weekday: Mon through Sun
DD = date: 01 through 31
Mmm = month: Jan through Dec
YYYY = year: 2000 through 2099
HH = hour: 00 through 24
MM = minutes: 00 through 59
SS = seconds: 00 through 59

X4$

= GMT offset

–12.0 through +14.0. Hours and minutes removed from GMT

X4%

= Daylight Saving Time

0 = Daylight Saving Time off or ignore

2 = Daylight Saving Time on (Europe)

1 = Daylight Saving Time on (North America)

3 = Daylight Saving Time on (Brazil)

X4^

= IP address

###.###.###.###

X4&

= Hardware (MAC) address

##‑##‑##‑##‑##‑##

X4*

= Number of open connections

0 – 255

X4(

= Password

12 alphanumeric characters

NOTE: The HTML language reserves certain characters for specific functions (see

Special Characters

on page 70).

X5)

= Domain name

Standard domain name rules apply (for example: xxx.com)

NOTE: The HTML language reserves certain characters for specific functions (see

Special Characters

on page 70). The @ character is

acceptable only as the lead‑in to the domain name (such as @extron.com).

X5!

= E‑mail account 1 through 5

65 – 69. 65 = e‑mail recipient 1, 66 = 2, 67 = 3, ... 69 = recipient 5

X5@

= E‑mail address

Typical e‑mail address format (for example: nnnn@xxx.com)

X5#

= Notification selections, part 1

I = inputs

F = fans

P = power supply

X5$

= Notification selections, part 2

If

X5#

=

I, then

X5$

= 00 (all inputs), or 01 through 32 (72) (input 1 through 32 [72])

If

X5#

=

F, then

X5$

= 00 (all fans)

If

X5#

=

P, then

X5$

= 00 (both power supplies).

X5%

= Notify when?

0 = no response

1 = fail/missing

2 = fixed/restored

3 = both 1 & 2

4 = suspend

X5^

= DHCP and SNMP

0 = off or disable, 1 = on or enable

X5&

= Port #

00 (all ports), 01 (rear panel), 02 (front panel), 03 – 99

X5*

= Baud rate

9600, 19200, 38400, 115200

X5(

= Parity

odd, even, none, mark, space (Only the first letter required.)

X6)

= Data bits

7, 8

X6!

= Stop bits

1, 2

X6@

= Port type

0 = RS‑232

1 = RS‑422

X6#

= Verbose mode

0 = clear/none (default for Telnet connection)

2 = tagged responses for queries

1 = verbose mode (default for RS‑232/RS‑422

3 = verbose mode and tagged for queries

NOTE: If tagged responses are enabled, all read commands return the constant string and the value as the set command does (for

example, the read matrix name command,

E

CN

}

returns Ipn•

X4)]

).

FOX Matrix 3200 and 7200 Switchers • Programming Guide

67