Command and Response Table for IP- and SNMP-Specific SIS Commands
Symbol definitions
X4)
= Matrix name
(Up to 24 alphanumeric characters)
NOTE: The HTML language reserves certain characters for specific functions (see
on page 70).
X4!
= Default name
Matrix 3200 — FOX-4G-Matrix-3- + last 3 pairs of MAC address
Matrix 7200 — FOX-4G-Matrix-7- + last 3 pairs of MAC address
X4@
= Time and date (for set)
In the format: MM/DD/YY•HH:MM:SS where:
MM = month: 01 (January) through 12 (December)
DD = day: 01 through 31
YY = year: 00 through 99
HH = hour: 00 through 23
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X4#
= Time and date (for read)
In the format: Day,•DD•Mmm•YYYY•HH:MM:SS where:
Day = weekday: Mon through Sun
DD = date: 01 through 31
Mmm = month: Jan through Dec
YYYY = year: 2000 through 2099
HH = hour: 00 through 24
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X4$
= GMT offset
–12.0 through +14.0. Hours and minutes removed from GMT
X4%
= Daylight Saving Time
0 = Daylight Saving Time off or ignore
2 = Daylight Saving Time on (Europe)
1 = Daylight Saving Time on (North America)
3 = Daylight Saving Time on (Brazil)
X4^
= IP address
###.###.###.###
X4&
= Hardware (MAC) address
##‑##‑##‑##‑##‑##
X4*
= Number of open connections
0 – 255
X4(
= Password
12 alphanumeric characters
NOTE: The HTML language reserves certain characters for specific functions (see
on page 70).
X5)
= Domain name
Standard domain name rules apply (for example: xxx.com)
NOTE: The HTML language reserves certain characters for specific functions (see
on page 70). The @ character is
acceptable only as the lead‑in to the domain name (such as @extron.com).
X5!
= E‑mail account 1 through 5
65 – 69. 65 = e‑mail recipient 1, 66 = 2, 67 = 3, ... 69 = recipient 5
X5@
= E‑mail address
Typical e‑mail address format (for example: nnnn@xxx.com)
X5#
= Notification selections, part 1
I = inputs
F = fans
P = power supply
X5$
= Notification selections, part 2
If
X5#
=
I, then
X5$
= 00 (all inputs), or 01 through 32 (72) (input 1 through 32 [72])
If
X5#
=
F, then
X5$
= 00 (all fans)
If
X5#
=
P, then
X5$
= 00 (both power supplies).
X5%
= Notify when?
0 = no response
1 = fail/missing
2 = fixed/restored
3 = both 1 & 2
4 = suspend
X5^
= DHCP and SNMP
0 = off or disable, 1 = on or enable
X5&
= Port #
00 (all ports), 01 (rear panel), 02 (front panel), 03 – 99
X5*
= Baud rate
9600, 19200, 38400, 115200
X5(
= Parity
odd, even, none, mark, space (Only the first letter required.)
X6)
= Data bits
7, 8
X6!
= Stop bits
1, 2
X6@
= Port type
0 = RS‑232
1 = RS‑422
X6#
= Verbose mode
0 = clear/none (default for Telnet connection)
2 = tagged responses for queries
1 = verbose mode (default for RS‑232/RS‑422
3 = verbose mode and tagged for queries
NOTE: If tagged responses are enabled, all read commands return the constant string and the value as the set command does (for
example, the read matrix name command,
E
CN
}
returns Ipn•
X4)]
).