Command and Response Table for SIS Commands

Symbol Definitions

]

= CR/LF (carriage return/line feed) (hex 0D 0A)

}

= Carriage return (no line feed, hex 0D)

|

= Pipe (can be used interchangeably with the

}

character)

• = Space character

E

= Escape key (hex 1B)

W

= Can be used interchangeably with the

E

character

X!

= Input number (for tie)

00 – 32 (FOX Matrix 3200) or 72 (FOX Matrix 7200) (00 = untied)

X@

= Output number

01 – 32 (FOX Matrix 3200) or 72 (FOX Matrix 7200)

X#

= Mute

0 = not muted

1 = muted

X$

= SFP or reclockable output number

00 – 32 or 72 (00 = global [SFP only])

X%

= Output reclocking rate

00 = auto (default)

01 = bypass

X^

= Laser control

0 = disable

1 = enable

2 = automatic

X&

= Global preset #

00 – 32 (3200) or 72 (7200) (00 = current configuration for view only)

X*

= Room number (for room presets)

01 – 10 maximum (each can have up to 10 presets (

X1)

) assigned)

NOTE: A Room is a subset of operator‑selected outputs that relate to each other. The FOX matrix switcher supports up to 10 rooms, each

of which can consist of 1 to 16 outputs.

X(

= Name

Up to 12 characters for input and output names and global and room preset names
Upper‑ and lower‑case alphanumeric characters and _ / and spaces are valid.

NOTE: The following characters are invalid or not recommended in the name: ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

X1)

= Room preset number

01 – 10 maximum

NOTE: A Room preset is a stored configuration with all outputs in a single room. A retrieved room preset becomes the current configuration.

X1!

= Connection status

0 = no input connected

1 = input connected

X1@

= Group number (for I/O grouping)

1 (group 1) through 4 (group 4) (or 0 = no group)

X1#

= Input number (for other than tie)

01 – 32 (FOX Matrix 3200) or 72 (FOX Matrix 7200)

X1$

= Lock mode status

0 = unlocked

1 = locked

X1%

= Number (quantity) of inputs

8, 16, 24, 32, 40, 48, 56, 64, or 72

X1^

= Number (quantity) of outputs

8, 16, 24, 32, 40, 48, 56, 64, or 72

X1&

= Board installed

0 = No board installed

4 = Non‑pathological multimode board

1 = Non‑reclocking multimode board*

5 = Non‑pathological singlemode board

2 = Non‑reclocking singlemode board*

6 = Pathological singlemode board

3 = 3G, SDI, HD‑SDI board

x = Unknown board or mix of transceivers

X1*

= I/O board slot number

1 – 9 (FOX Matrix 7200) or 1 – 4 (FOX Matrix 3200)

X1(

= Transceiver module installed

0 = No module installed
1 = Non‑pathological multimode module

3 = 3G‑SDI, HD‑SDI, SD‑SDI module

2 = Non‑pathological singlemode module

4 = Pathological singlemode module

X2)

= Transceiver module number

01 – 72 (or maximum number of transceiver modules for your configuration)

X2!

= Vendor/manufacturer name

X2@

= Transmit output power in milliwatts

X2#

= Receive optical power in milliwatts

X2$

= SFP temperature

Degrees Celsius

X2%

= Firmware version number to second decimal place (x.xx)

X2^

= Verbose firmware version‑description‑upload date/time. See the Query controller firmware version (verbose) command on

page 65

.

X2&

= Voltage

Positive or negative voltage and magnitude

X2*

= Temperature

Degrees Fahrenheit

X2(

= Fan speed

In revolutions per minute (RPM)

* Legacy board, no longer manufactured, identified for completeness only

X1)

= Output rate:

nnnn = actual rate (in MHz)

0000 = no connection or rate

mismatch
‑ ‑ ‑ ‑ = bypass mode

X2@

= Reclocking status

0 = Signal reclocked

1 = Signal not reclocked

X2@

= Reclocking status

0

= Signal reclocked

1

= Signal not

reclocked