Command and response table for sis commands, Command and response table for sis, Commands – Extron Electronics FOX Matrix 7200 User Manual
Page 66: Next, And used thr, Symbol definitions
Command and Response Table for SIS Commands
Symbol Definitions
]
= CR/LF (carriage return/line feed) (hex 0D 0A)
}
= Carriage return (no line feed, hex 0D)
|
= Pipe (can be used interchangeably with the
}
character)
• = Space character
E
= Escape key (hex 1B)
W
= Can be used interchangeably with the
E
character
X!
= Input number (for tie)
00 – 32 (FOX Matrix 3200) or 72 (FOX Matrix 7200) (00 = untied)
X@
= Output number
01 – 32 (FOX Matrix 3200) or 72 (FOX Matrix 7200)
X#
= Mute
0 = not muted
1 = muted
X$
= SFP or reclockable output number
00 – 32 or 72 (00 = global [SFP only])
X%
= Output reclocking rate
00 = auto (default)
01 = bypass
X^
= Laser control
0 = disable
1 = enable
2 = automatic
X&
= Global preset #
00 – 32 (3200) or 72 (7200) (00 = current configuration for view only)
X*
= Room number (for room presets)
01 – 10 maximum (each can have up to 10 presets (
X1)
) assigned)
NOTE: A Room is a subset of operator‑selected outputs that relate to each other. The FOX matrix switcher supports up to 10 rooms, each
of which can consist of 1 to 16 outputs.
X(
= Name
Up to 12 characters for input and output names and global and room preset names
Upper‑ and lower‑case alphanumeric characters and _ / and spaces are valid.
NOTE: The following characters are invalid or not recommended in the name: ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X1)
= Room preset number
01 – 10 maximum
NOTE: A Room preset is a stored configuration with all outputs in a single room. A retrieved room preset becomes the current configuration.
X1!
= Connection status
0 = no input connected
1 = input connected
X1@
= Group number (for I/O grouping)
1 (group 1) through 4 (group 4) (or 0 = no group)
X1#
= Input number (for other than tie)
01 – 32 (FOX Matrix 3200) or 72 (FOX Matrix 7200)
X1$
= Lock mode status
0 = unlocked
1 = locked
X1%
= Number (quantity) of inputs
8, 16, 24, 32, 40, 48, 56, 64, or 72
X1^
= Number (quantity) of outputs
8, 16, 24, 32, 40, 48, 56, 64, or 72
X1&
= Board installed
0 = No board installed
4 = Non‑pathological multimode board
1 = Non‑reclocking multimode board*
5 = Non‑pathological singlemode board
2 = Non‑reclocking singlemode board*
6 = Pathological singlemode board
3 = 3G, SDI, HD‑SDI board
x = Unknown board or mix of transceivers
X1*
= I/O board slot number
1 – 9 (FOX Matrix 7200) or 1 – 4 (FOX Matrix 3200)
X1(
= Transceiver module installed
0 = No module installed
1 = Non‑pathological multimode module
3 = 3G‑SDI, HD‑SDI, SD‑SDI module
2 = Non‑pathological singlemode module
4 = Pathological singlemode module
X2)
= Transceiver module number
01 – 72 (or maximum number of transceiver modules for your configuration)
X2!
= Vendor/manufacturer name
X2@
= Transmit output power in milliwatts
X2#
= Receive optical power in milliwatts
X2$
= SFP temperature
Degrees Celsius
X2%
= Firmware version number to second decimal place (x.xx)
X2^
= Verbose firmware version‑description‑upload date/time. See the Query controller firmware version (verbose) command on
.
X2&
= Voltage
Positive or negative voltage and magnitude
X2*
= Temperature
Degrees Fahrenheit
X2(
= Fan speed
In revolutions per minute (RPM)
* Legacy board, no longer manufactured, identified for completeness only
X1)
= Output rate:
nnnn = actual rate (in MHz)
0000 = no connection or rate
mismatch
‑ ‑ ‑ ‑ = bypass mode
X2@
= Reclocking status
0 = Signal reclocked
1 = Signal not reclocked
X2@
= Reclocking status
0
= Signal reclocked
1
= Signal not
reclocked
FOX Matrix 3200 and 7200 Switchers • Programming Guide
58