beautypg.com

Extron Electronics FOX Matrix 7200 User Manual

Page 74

background image

Command and Response Table for SIS Commands (continued)

NOTE:

X2&

= Voltage

Positive or negative voltage and magnitude

X2*

= Temperature

Degrees Fahrenheit

X2(

= Fan speed

In revolutions per minute (RPM)

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

Information requests (continued)

Request system status

S

FOX Matrix 3200 Response:

X2&

X2&

X2&

X2&

X2&

X2&

X2&

X2*

X2(

X2(]

FOX Matrix 7200 Response:

X2&

X2&

X2&

X2&

X2&

X2&

X2&

X2*

X2(

X2(

X2(

X2(]

Response description (

FOX Matrix 3200):

+3.3V•+5V•+1.3V•+1.2V•+12V (fan volts)•+12V (redundant PS)•+12V (primary PS)•Temp•Fan 1 RPM•Fan 2 RPM

]

Response description (

FOX Matrix 7200):

+3.3V•+5V•+1.3V•+1.2V•+12V (fan volts)•+12V (redundant PS)•+12V (primary PS)•Temp•Fan 1 RPM•Fan 2 RPM•Fan 3 RPM•Fan 4 RPM

]

Example (

Matrix 3200):

S

Backplane receiving 12.00 V

Internal temperature 80.6° F

Fan 1 rotating at 3,013 RPM

3.3 V power system at 3.27 V

3.27•4.95•1.28•1.22•12.00•12.06•12.12•+080.60•03013•02860

FOX Matrix 3200 and 7200 Switchers • Programming Guide

66

This manual is related to the following products: