beautypg.com

Extron Electronics FOX Matrix 7200 User Manual

Page 71

background image

Command and Response Table for SIS Commands (continued)

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

I/O grouping

NOTE: The group that is assigned in each of the following I/O grouping commands (

X1@

) must be 1, 2, 3, 4, or 0 (not grouped).

Write input grouping

EX1@

1

X1@

2

...

X1@

n

I

}

Gri

X1@

1

X1@

2

X1@

3

...

X1@

n

]

Each

X1@

entry is the group number assigned to

an input, starting from input 1.
n is the highest‑numbered input.

Example (

16 x 16 matrix):

E

40133000044...4I

}

See below.

Input 1 is in Group 4,
Input 2 is in Group 0 (not grouped), ...
Input 16 is in Group 4.

01

Input:

Gri

Response #s = group:

Input 1 in group 4

02 03 04 05 06 07 08 09 10

15 16

11 12 13 14

Input 2 not grouped

Input 16 in group 4

4 0 1 3 3 0 0 0 0 4

4 4

0 0 0 4

Write output grouping

EX1@

1

X1@

2

...

X1@

n

O

}

Gro

X1@

1

X1@

2

X1@

3

...

X1@

n

]

Each

X1@

entry is the group number assigned to

an output, starting from output 1.
n

is the highest‑numbered output.

Read input grouping

E

I

}

X1@

1

X1@

2

X1@

3

...

X1@

n

]

Each

X1@

entry is the group number assigned to

an input, starting from input 1.
n

is the highest‑numbered input.

Example (

8 x 8 matrix):

E

I

}

01

Input:

Response = group:

Input 1 in group 1

02 03 04 05 06 07 08

Input 8 not grouped

1 1 1 3 3 0 0 0

Read output grouping

E

O

}

X1@

1

X1@

2

X1@

3

...

X1@

n

]

Each

X1@

entry is the group number assigned to

an output, starting from output 1.
n

is the highest‑numbered output.

Names

NOTES:

The HTML language reserves certain characters for specific functions (see

Special Characters

on page 70).

Do not use leading spaces in preset names.

If a preset is unassigned, the name (

X(

) displays [unassigned].

If a global preset is saved, but not yet named, the default name is Preset•

X&

.

If a room preset is saved, but not yet named, the default name is Rm

X*

•Prst

X1)

.

Write global preset name

EX&

,

X(

NG

}

Nmg

X&

,

X(]

Example:

E

1,Security 1NG

}

Nmg01,Security 1

]

Name global preset 1 “Security 1.”

Read global preset name

EX&

NG

}

X(]

Example:

E

2NG

}

Security 2

]

Global preset 2 is named “Security 2.”

Write room preset name

EX*

*

X1)

,

X(

NP

}

Nmp

X*

*

X1)

,

X(]

Example:

E

1*3,Podium_DVDNP

}

Nmp01*3,Podium_DVD

]

Name room 1, preset 3 “Podium_DVD.”

Read room preset name

EX*

*

X1)

NP

}

X(]

Write input name

EX1#

,

X(

NI

}

Nmi

X1#

,

X(]

Example:

E

1,Podium camNI

}

Nmi01,Podium cam

]

Name input 1 “Podium cam.”

Read input name

EX1#

NI

}

X(]

Write output name

EX@

,

X(

NO

}

Nmo

X@

,

X(]

Example:

E

1,Main PJ1NO

}

Nmo01,Main PJ1

]

Name output 1 “Main PJ1.”

Read output name

EX@

NO

}

X(]

NOTE:

X@

= Output number

01 – (maximum number of outputs for your configuration)

X&

= Global preset number

00 – 32 (FOX Matrix 3200) or 64 (FOX Matrix 7200) (00 = current configuration)

X*

= Room # (for room presets)

01 – 10 (each can have up to 10 presets (

X(

s) assigned)

X(

= Room name

12 characters maximum

X1)

= Room preset number

00 – 10 maximum (0 = current configuration for room)

X1@

= Group number (for I/O grouping)

1 (group 1) through 4 (group 4) (or 0 = no group)

X1#

= Input number (for other than tie)

01 – (maximum number of inputs for your configuration)

FOX Matrix 3200 and 7200 Switchers • Programming Guide

63

This manual is related to the following products: