beautypg.com

H-3531 – Xylem H-3531 FlashLite User Manual

Page 65

background image

H-3531

SDI-12 Command and Response Protocol 5-27

5.20.6 H-355 Read/Write Purge Threshold Command
This command is for reading the current purge threshold and also for editing the purge
threshold. The user can change the purge threshold from 10 to 65 psi. Refer to H-355 Gas
Purge System manual for more details.

Command

Response

Description

“aXRPT!”

“a0051

Read Purge Threshold

“aXWPTdd!”

“a0051

Write Purge Threshold

Where:

a

is the sensor address ("0-9", "A-Z", "a-z", "*", "?").

XRPT

are upper case characters.

XWPT

are upper case characters.

dd

is the purge threshold desired(10-65)

This command takes 005 seconds to complete and places 1 value in the data buffer. Use
the “aD0" command to collect and view the current value.

Example of a H-3531 Extended "Read Purge Threshold" command:
Command

Response

Time

Values

Description

"aXRPT!"

"a0051"

5 sec

1

Read Purge Threshold

Command

Response

Description

"aD0!"

"a+15"

15 PSI Purge Threshold

Example of a H-3531 Extended "Write Purge Threshold" command:
Command

Response

Time

Values

Description

"aXWPT20!"

"a0051"

5 sec

1

Write Purge Threshold

Command

Response

Description

"aD0!"

"a+20"

20 PSI Purge Threshold