SDI-12 Command and Response Protocol 5-25

5.20.4 H-355 Read/Write Purge Duration Command
This command is for reading the current purge duration and also for editing the purge
duration. The user can change the purge duration from 10 to 240 seconds. Refer to H-355
Gas Purge System manual for more details.

Command

Response

Description

“aXRPD!”

“a0051

Read Purge Duration

“aXWPDddd!”

“a0051

Write Purge Duration

Where:

a

is the sensor address ("0-9", "A-Z", "a-z", "*", "?").

XRPD

are upper case characters.

XWPD

are upper case characters.

ddd

is the purge duration value desired(10-240).

This command takes 005 seconds to complete and places 1 value in the data buffer. Use
the “aD0" command to collect and view the current value.

Example of a H-3531 Extended "Read Purge Duration" command:
Command

Response

Time

Values

Description

"aXRPD!"

"a0051"

5 sec

1

Read Purge Duration

Command

Response

Description

"aD0!"

"a+30"

30 seconds

Example of a H-3531 Extended "Write Purge Duration" command:
Command

Response

Time

Values

Description

"aXWPD60!"

"a0051"

5 sec

1

Write Purge Duration

Command

Response

Description

"aD0!"

"a+60"

60 seconds