beautypg.com

5 operation under unusual conditions – Armasight NAM601500126DH1 PVS14/6015 GEN 2+ HD Multi-Purpose Night Vision Monocular User Manual

Page 44

background image

44

3.4.9. PREPARATION FOR STORAGE

(1) Perform the following to shut down the monocular.

(a) Turn the monocular OFF.

(b) Remove the monocular from the headmount, helmet mount or weapon, and remove the weap-

on mount from the monocular.

WARNING

:

Do not carry batteries in pockets containing metal objects such as coins, keys, etc. Metal objects

can cause the batteries to short circuit and become very hot when inserted into the device.

(2) Packaging After Use.

(a) Remove the battery cap and battery.

(b) Inspect the battery housing for corrosion or moisture. Clean and dry if necessary.

(c) Replace the battery cap.

(d) If installed, remove the demist shield or sacrificial window. Replace the objective lens cap.

NOTE

:

• Prior to placing the MUNVM into the carrying case, verify that the MUNVM and the case are

both free of dirt, dust, and moisture.
• The monocular and helmet mount should not be left on the helmet when the helmet is re-

moved.

(e) Refer to Figure 2-1 for proper placement of the demist shield, battery, carrying case strap, lens

paper, sacrificial window, manual, browpads, headmount, helmet mount, headmount/ helmet mount

adapter and weapon mount.

(f) Place the monocular into the shallow pocket of the carrying case.

(g) Place the carrying case into the shipping and storage case; close and latch the case (Figure 2-3).

(h) Return the case to the storage area.

3.5 OPERATION UNDER UNUSUAL CONDITIONS

3.5.1. OPERATION IN DUSTY OR SANDY AREAS

CAUTION

:

Operation in dusty or sandy areas can gouge and scratch the optical elements, and damage the

mechanical components. unless the below precautions are observed.

(1) Verify that the sacrificial window is in place.
(2) Avoid pointing the monocular into the wind unless it is absolutely necessary.
(3) Keep the carrying case closed unless removing or replacing items.
(4) Ensure that all dust and sand is removed from the MUNVM and carrying case after operation.