beautypg.com

Asus GigaX2008EX User Manual

Page 52

background image

42

GigaX2008EX L2 Managed Switch User Manual

CLI command: l2 vlan remove
CLI command: l2 vlan utportadd

[Remove VLAN]
Allows user to completely destroy an existing VLAN.

CLI command: l2 vlan delete

[Reload]
Restores the previous saved settings from configuration file.

CLI command: l2 vlan retrieve

[Show Port]
Displays the port configuration

CLI command: l2 port show

[PVID]
Sets the default VLAN for a port by giving a VLAN ID and its associated port

member list.

CLI command: l2 port vlan

[CoS Value]
Sets the Class of Service for a port by assigning it a priority (with range of 0-7)

criteria value for untagged packets..

CLI command: l2 port priority

[Reload]
Restores the previous saved settings from configuration file.

CLI command: l2 port retrieve

[CoS] [Map]
Allows user to map the CoS priority (with range of 0-7) for a buffer queue (total

of 4, with queue ID of 1-4).

CLI command: l2 cos map

[Scheduling Algorithm] [Strict/WRR]
Allows user to set scheduling with strict priority based or weight priority based.

CLI command: l2 cos sched