Smart fan control [smart fan ii, System1/2 target temperature, Scroll down to display more items – Asus RS260-E4/RX8 User Manual

Page 118

background image

5-32

Chapter 5: BIOS setup

Scroll down to display more items:

CPU1/2 Domain 0/1 Temperature, SYSTEM1/2 Temperature,

CPU_FAN1/2 Speed, FRN_FAN1/2/3/4 Speed, REAR_FAN1/2 Speed

These fields show the auto-detected values and are not user-configurable. If no fan

is installed, the field shows 0 RPM.

Smart Fan Control [Smart Fan II]

Allows you to disable or configure the Smart Fan feature.

Configuration options: [Disabled] [Smart Fan] [Smart Fan II]

CPU1/2 Domain 0/1 Target Temperature (CPU1/2 Target Temperature)

Allows you to set the target CPU temperature at which the CPU fan will run at full

speed. Configuration options: [44ºC] ~ [66ºC]

SYSTEM1/2 Target Temperature

Allows you to set the target sytem temperature at which the system fan will start

running if the fan is not yet turned on.

Configuration options: [39ºC] ~ [60ºC]

FBD_FAN1/2 Speed, VCORE0/1 Voltage, VTT, +1.5V, +1.8V, +3V, +12V,

+5V, +5VSB, VBAT

These fields show the auto-detected values and are not user-configurable.

PhoenixBIOS Setup Utility

Advanced

Item Specific Help

Full fan speed will

be started when the

temperature reaches the

selected target value.

Hardware Monitor

CPU1 Domain 0 Target Temperature

[72ºC]

CPU1 Domain 1 Target Temperature

[72ºC]

CPU2 Domain 0 Target Temperature

[72ºC]

CPU2 Domain 1 Target Temperature

[72ºC]

SYSTEM1 Target Temperature

[60ºC]

SYSTEM2 Target Temperature

[60ºC]

FBD_FAN1 Speed

N/A

VCORE0 Voltage

1.25 V

VCORE1 Voltage

1.25 V

VTT

1.21 V

+1.5V

1.56 V

+1.8V

1.79 V

+3V

3.28 V

+12V

11.91 V

+5V

4.87 V

+5VSB

4.96 V

VBAT

3.10 V

F1:Help ↑↓ : Select Item -/+: Change Value

F5: Setup Defaults