GE Industrial Solutions 6KCV300lNS User Manual
Page 29

S
The parameter 5EFEh is used to control the virtual digital input previously configured; the status of the single
Bits controls the virtual
input assigned to the Bit during the configuration:
OBJECT ATTRIBUTE
MEANING
Index
Value (drive)
virtual digital input
Object code
07
I
Single variable
Index of the type of datum
05
The status of the single Bit controls the
virtual digital input assigned
Length
Password
Access group
02
2 Byte
00
Non-existing
00
Non-existing
Access rights
02
Write-Ail
Local address
I
x x x x
Specific
11.2
Virtual digital output
As for the virtual digital output the parameters used to control are:
Parameter index 5EFDh:
virtual digital output.
Parameter index 5EFFh: reading of the values virtual digital output.
Parameter
element array Unsigned Int.
This array is used to configure the virtual digital output; it has to be written before using the virtual digital
output. It has the drive codes assigned to the the output; these outputs are then controlled through the
parameter
type Unsigned Int where the status of the single Bits corresponds to the status of the
virtual digital output assigned during the configuration.
Example:
The elemenf I of fhe parameter array
contains
parameter index
referring to fhe
AV300 drive, which means Drive-Ready.
The functioning is the following: after configuring the element of the parameter
with the
parameter
index
the status Drive-Ready of the the
drive is read fhrough fhe
0 of the
paramefer