Figure 40 output connectors, Table 7 output connector pinout – GE Industrial Solutions CPS3200U User Manual
Page 41

CPS3200U Upstream System – 23” Product Manual
CPS3200U
CC848779826 r09 December 2013
41
Figure 40 Output Connectors
Wireset Connector: RJ-21 type 50 pin plug:
• 22 AWG solid or stranded AMP 552173-1 or equivalent.
• 24 AWG solid or stranded or 26 AWG solid AMP 229974-1 or equivalent.
• The connector shall be arranged with a right angle housing such that the cable exits to the pin 1 side.
Table 7 Output Connector Pinout
Connector for Circuits 1-8 (Shelf J1)
Connector for Circuits 9-16 (Shelf J2)
Conv Out Pos Color
Conv Out Pos Color
Conv Out Pos Color
Conv Out Pos Color
1a-
1 BL / W
1a+
26 W / BL
9a-
1 BL / W
9a+
26 W / BL
1b-
2 O / W
1b+
27 W / O
9b-
2 O / W
9b+
27 W / O
2a-
3 G / W
2a+
28 W / G
10a-
3 G / W
10a+
28 W / G
2b-
4 BR / W
2b+
29 W / BR
10b-
4 BR / W
10b+
29 W / BR
3a-
5 SL / W
3a+
30 W / SL
11a-
5 SL / W
11a+
30 W / SL
3b-
6 BL / R
3b+
31 R / BL
11b-
6 BL / R
11b+
31 R / BL
4a-
7 O / R
4a+
32 R / O
12a-
7 O / R
12a+
32 R / O
4b-
8 G / R
4b+
33 R / G
12b-
8 G / R
12b+
33 R / G
5a-
9 BR / R
5a+
34 R / BR
13a-
9 BR / R
13a+
34 R / BR
5b-
10 SL / R
5b+
35 R / SL
13b-
10 SL / R
13b+
35 R / SL
6a-
11 BL / BK
6a+
36 BK / BL
14a-
11 BL / BK
14a+
36 BK / BL
6b-
12 O / BK
6b+
37 BK / O
14b-
12 O / BK
14b+
37 BK / O
7a-
13 G / BK
7a+
38 BK / G
15a-
13 G / BK
15a+
38 BK / G
7b-
14 BR / BK
7b+
39 BK / BR
15b-
14 BR / BK
15b+
39 BK / BR
8a-
15 SL / BK
8a+
40 BK / SL
16a-
15 SL / BK
16a+
40 BK / SL
8b-
16 BL / Y
8b+
41 Y / BL
16b-
16 BL / Y
16b+
41 Y / BL
spare
17 O / Y
spare
42 Y / O
spare
17 O / Y
spare
42 Y / O
spare
18 G / Y
spare
43 Y / G
spare
18 G / Y
spare
43 Y / G
spare
19 BR / Y
spare
44 Y / BR
spare
19 BR / Y
spare
44 Y / BR
spare
20 SL / Y
spare
45 Y / SL
spare
20 SL / Y
spare
45 Y / SL
spare
21 BL / V
spare
46 V / BL
spare
21 BL / V
spare
46 V / BL
spare
22 O / V
spare
47 V / O
spare
22 O / V
spare
47 V / O
spare
23 G / V
spare
48 V / G
spare
23 G / V
spare
48 V / G
spare
24 BR / V
spare
49 V / BR
spare
24 BR / V
spare
49 V / BR
*FR GRD
25 SL / V
*FR GRD
50 V / SL
*FR GRD
25 SL / V
*FR GRD
50 V / SL
*EMI performance is enhanced when the output cable shield is grounded only at the CPS3200 end of the shield.