Electrical Specifications
(continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
Dynamic Load Response
(dIo/dt=0.1A/
s; V
IN
= V
IN, nom
; T
A
=25°C)
Load Change from Io= 50% to 75% or 25% to
50% of Io,max;
Peak Deviation
All
V
pk
3
% V
O, set
Settling Time (Vo<10% peak deviation)
All t
s
200
s
(dIo/dt=1A/
s; V
IN
= V
IN, nom
; T
A
=25°C)
Load Change from Io= 50% to 75% or 25% to
50% of Io,max;
Peak Deviation
All
V
pk
5
% V
O, set
Settling Time (Vo<10% peak deviation)
All t
s
200
s
Isolation Specifications
Parameter
Device
Symbol
Min
Typ
Max
Unit
Isolation Capacitance
All
C
iso
1000
pF
Isolation Resistance
All
R
iso
10
MΩ
I/O Isolation Voltage (100% factory Hi-pot tested)
All
All
1500 V
dc
General Specifications
Parameter
Device
Symbol
Min
Typ
Max
Unit
Calculated Reliability based upon Telcordia SR-
332 Issue 2: Method
I
Case 3 (I
O
=80%I
O, max
,
T
A
=40°C, airflow = 200 lfm, 90% confidence)
B FIT
334
10
9
/Hours
A-S FIT
290
10
9
/Hours
F FIT
328
10
9
/Hours
Y FIT
302
10
9
/Hours
B MTBF
2,997,896
Hours
A-S MTBF
3,451,558
Hours
F MTBF
3,051,626
Hours
Y MTBF
3,312,888
Hours
Weight All
20.5
(0.72)
g
(oz.)