Af-600 fp high power operating instructions – GE Industrial Solutions AF-600 FP Fan and Pump Drive (460V_575V 150HP and above) User Manual
Page 157

Mains Supply 3 x 380 - 480 VAC
P500
P560
P630
P710
P800
P1M0
Typical Shaft output
at 400 V [kW]
500
560
630
710
800
1000
Typical Shaft output
at 460 V [HP]
650
750
900
1000
1200
1350
Unit Size IP21, 54
without/ with options
cabinet
61/63
61/63
61/63
61/63
62/64
62/64
Output current
Continuous
(at 400 V) [A]
880
990
1120
1260
1460
1720
Intermittent (60 sec
overload)
(at 400 V) [A]
968
1089
1232
1386
1606
1892
Continuous
(at 460 V) [A]
780
890
1050
1160
1380
1530
Intermittent (60 sec
overload)
(at 460 V) [A]
858
979
1155
1276
1518
1683
Continuous KVA
(at 400 V) [KVA]
610
686
776
873
1012
1192
Continuous KVA
(at 460 V) [KVA]
621
709
837
924
1100
1219
Max. input current
Continuous
(at 400 V ) [A]
857
964
1090
1227
1422
1675
Continuous (at 460 V)
[A]
759
867
1022
1129
1344
1490
Max. cable size,motor
[mm
2
(AWG
2)
)]
8x150
(8x300 mcm)
12x150
(12x300 mcm)
Max. cable size,mains
[mm
2
(AWG
2)
)]
8x240
(8x500 mcm)
Max. cable size, load-
sharing [mm
2
(AWG
2)
)]
4x120
(4x250 mcm)
Max. cable size, brake
[mm
2
(AWG
2)
)
4x185
(4x350 mcm)
6x185
(6x350 mcm)
Max. external pre-
fuses [A]
1
1600
2000
2500
Estimated power loss
at rated max. load
[W]
4)
Weight,
Unit Size IP21, IP 54
[kg]
1004/ 1299
1004/ 1299
1004/ 1299
1004/ 1299
1246/ 1541
1246/ 1541
Weight Rectifier Mod-
ule [kg]
102
102
102
102
136
136
Weight Inverter Mod-
ule [kg]
102
102
102
136
102
102
Efficiency
4)
0.98
Output frequency
0-600 Hz
Heatsink overtemp.
trip
95 °C
Power card ambient
trip
68 °C
AF-600 FP High Power Operating Instructions
155
8