Af-600 fp high power operating instructions – GE Industrial Solutions AF-600 FP Fan and Pump Drive (460V_575V 150HP and above) User Manual
Page 156

Mains Supply 3 x 380 - 480 VAC
P315
P355
P400
P450
Typical Shaft output at 400 V
[kW]
315
355
400
450
Typical Shaft output at 460 V
[HP]
450
500
550 600
Unit Size IP21
51
51
51
51
Unit SizeIP54
51
51
51
51
Unit Size IP00
52
52
52
52
Output current
Continuous
(at 400 V) [A]
600
658
745
800
Intermittent (60 sec over-
load)
(at 400 V) [A]
660
724
820
880
Continuous
(at 460 V) [A]
540
590
678
730
Intermittent (60 sec over-
load)
(at 460 V) [A]
594
649
746
803
Continuous KVA
(at 400 V) [KVA]
416
456
516
554
Continuous KVA
(at 460 V) [KVA]
430
470
540
582
Max. input current
Continuous
(at 400 V ) [A]
590
647
733
787
Continuous
(at 460 V) [A]
531
580
667
718
Max. cable size, mains, mo-
tor and load share [mm
2
(AWG
2)
)]
4x240
(4x500 mcm)
4x240
(4x500 mcm)
4x240
(4x500 mcm)
4x240
(4x500 mcm)
Max. cable size, brake [mm
2
(AWG
2)
)
2 x 185
(2 x 350 mcm)
2 x 185
(2 x 350 mcm)
2 x 185
(2 x 350 mcm)
2 x 185
(2 x 350 mcm)
Max. external pre-fuses [A]
1
700
900
900
900
Estimated power loss
at rated max. load [W]
4)
7630
7701
8879
9428
Weight,
Unit Size IP21, IP 54 [kg]
263
270
272
313
Weight,
Unit Size IP00 [kg]
221
234
236
277
Efficiency
4)
0.98
Output frequency
0 - 600 Hz
Heatsink overtemp. trip
95 °C
Power card ambient trip
68 °C