Af-600 fp high power operating instructions, 17 ap -## hvac appl. p aram – GE Industrial Solutions AF-600 FP Fan and Pump Drive (460V_575V 150HP and above) User Manual
Page 143

Par
. No.
#
Pa
ram
et
er d
escri
ption
De
fa
ul
t va
lu
e
4-set-u
p
Ch
an
ge
du
rin
g
ope
ra-
tion
Co
nv
er
-
sion inde
x
Typ
e
AP
-0#
AP-0
0
Ex
ternal Inte
rlock Delay
0 s
All se
t-u
ps
TR
U
E
0
U
int16
AP
-2#
AP-2
0
Lo
w P
owe
r Au
to
Se
t-up
[0
] Of
f
All set-ups
FA
LSE
-
U
int8
AP-2
1
Lo
w P
owe
r De
tecti
on
[0] Disabled
All se
t-u
ps
TR
U
E
-
Ui
nt
8
AP-2
2
Low Spe
ed
De
te
ct
ion
[0] Disabled
All
set-ups
TR
U
E
-
U
int8
AP-2
3
No
-Fl
ow
Func
tio
n
[0
] Of
f
All se
t-u
ps
TR
U
E
-
Ui
nt
8
AP-2
4
N
o-Flow D
el
ay
10 s
All set-u
ps
TR
U
E
0
Ui
nt16
AP-2
6
Dr
y P
ump
F
uncti
on
[0
] Of
f
All se
t-u
ps
TR
U
E
-
Ui
nt
8
AP-2
7
D
ry
Pu
mp
Del
ay
10 s
All set-u
ps
TR
U
E
0
Ui
nt16
AP
-3#
AP-3
0
N
o-Flow P
ower
0.
00
k
W
All se
t-u
ps
TR
U
E
1
U
int32
AP-3
1
Po
wer C
orr
ecti
on
Factor
10
0 %
All se
t-u
ps
TR
U
E
0
Uin
t16
AP-3
2
Low Spe
ed
[R
PM]
Ex
pr
essio
nLimit
All set-ups
TR
U
E
67
U
int16
AP-3
3
Lo
w S
pee
d [
H
z]
Ex
pr
essio
nLimit
All se
t-u
ps
TR
U
E
-1
Uin
t16
AP-3
4
Low Spe
ed
Powe
r [kW]
Ex
pr
essio
nLimit
All set-ups
TR
U
E
1
Uint32
AP-3
5
Lo
w Spe
ed
Powe
r [HP]
Ex
pr
essio
nLimit
All se
t-u
ps
TR
U
E
-2
Uin
t32
AP-3
6
H
ig
h S
pee
d
[RPM]
Ex
pr
essio
nLimit
All set-ups
TR
U
E
67
U
int16
AP-3
7
Hi
gh
S
pee
d
[H
z]
Ex
pr
essio
nLimit
All se
t-u
ps
TR
U
E
-1
Uin
t16
AP-3
8
H
ig
h
Sp
ee
d Power
[k
W]
Ex
pr
essio
nLimit
All set-ups
TR
U
E
1
Uint32
AP-3
9
Hi
gh
S
pee
d Power
[HP]
Ex
pr
essio
nLimit
All se
t-u
ps
TR
U
E
-2
Uin
t32
AP
-4#
AP-4
0
Mi
nim
um Ru
n Ti
me
10 s
All se
t-u
ps
TR
U
E
0
Uin
t16
AP-
41
M
in
im
um
Sl
ee
p T
im
e
10 s
All set-u
ps
TR
U
E
0
Ui
nt16
AP-4
2
Wak
e-u
p Sp
ee
d
[RPM]
Ex
pr
essio
nLimit
All se
t-u
ps
TR
U
E
67
Uin
t16
AP
-43
W
ak
e-u
p Sp
ee
d
[Hz]
Ex
pr
essio
nLimit
All set-ups
TR
U
E
-1
U
int16
AP-4
4
Wak
e-
up R
ef./F
B Di
ff
er
en
ce
10 %
All se
t-u
ps
TR
U
E
0
In
t8
AP-4
5
Setp
oin
t Boost
0 %
All set-ups
TR
U
E
0
In
t8
AP-4
6
Ma
ximu
m B
oo
st
Tim
e
60 s
All se
t-u
ps
TR
U
E
0
Uin
t16
AP
-5#
AP-5
0
En
d o
f C
ur
ve
F
unct
ion
[0
] Of
f
All se
t-u
ps
TR
U
E
-
Ui
nt
8
AP-5
1
End
of C
urv
e De
lay
10 s
All set-u
ps
TR
U
E
0
Ui
nt16
AP
-6#
AP-6
0
Br
ok
en
Be
lt Fu
nc
tion
[0
] Of
f
Al
l set-up
s
TRUE
-
U
int8
AP-6
1
Br
ok
en
Be
lt T
orq
ue
10 %
All se
t-u
ps
TR
U
E
0
Ui
nt
8
AP
-62
Br
oke
n B
elt D
ela
y
10 s
All set-u
ps
TR
U
E
0
Ui
nt16
AP
-7#
AP-7
5
Sh
ort C
ycl
e Pr
otecti
on
[0] Disabled
Al
l set-up
s
TRUE
-
U
int8
AP-7
6
Inte
rv
al
betwe
en Starts
st
art_to_sta
rt_min_on_
time
(P22
77)
All se
t-u
ps
TR
U
E
0
Uin
t16
AP
-77
M
in
im
um Ru
n Ti
me
0 s
All set-u
ps
TR
U
E
0
Ui
nt16
AP
-8#
AP-8
0
Fl
ow C
om
pen
sati
on
[0] Disabled
Al
l set-up
s
TRUE
-
U
int8
AP-8
1
Sq
ua
re
-lin
ea
r Cu
rv
e
Ap
pr
ox
im
at
io
n
10
0 %
All se
t-u
ps
TR
U
E
0
Ui
nt
8
AP-8
2
W
or
k Poin
t C
alc
ul
at
ion
[0] Disabled
All
set-ups
TR
U
E
-
U
int8
AP-8
3
Sp
ee
d a
t N
o-Flo
w [RP
M
]
Ex
pr
essio
nLimit
All se
t-u
ps
TR
U
E
67
Uin
t16
AP-8
4
Spe
ed at No-F
lo
w
[Hz
]
Ex
pr
essio
nLimit
All set-ups
TR
U
E
-1
U
int16
AP-8
5
Sp
ee
d a
t De
si
gn
P
oin
t [RP
M
]
Ex
pr
essio
nLimit
All se
t-u
ps
TR
U
E
67
Uin
t16
AP-8
6
Spe
ed at
D
esig
n
Poi
nt
[Hz]
Ex
pr
essio
nLimit
All set-ups
TR
U
E
-1
U
int16
AP-8
7
Pr
essure at
No-Flow
Sp
ee
d
0.000
N/A
All se
t-u
ps
TR
U
E
-3
In
t3
2
AP-8
8
Pr
essu
re at
Ra
ted
Sp
eed
999999.99
9 N
/A
All set-u
ps
TR
U
E
-3
In
t32
AP-8
9
Fl
ow at D
esi
gn
Poi
nt
0.000
N/A
All se
t-u
ps
TR
U
E
-3
In
t3
2
AP
-9#
AP-9
0
Flo
w
at
Ra
te
d Sp
ee
d
0.000
N/A
All se
t-u
ps
TR
U
E
-3
In
t3
2
7.2.
17
AP
-## HVAC Appl. P
aram
.
AF-600 FP High Power Operating Instructions