Effect of crosstalk, Influence quantities – Rainbow Electronics AT73C502 User Manual
Page 25

AT73C500
25
The measurements are done according to IEC1036 specifi-
cation. The results are averaged over a period of 10s.
Before measurements, AT73C500 devices have been
operational for minimum 1h.
Effect of Crosstalk
The error caused by crosstalk from one current input to
other two current inputs when the meter is carrying a sin-
gle-phase load.
Influence Quantities
The additional error caused by different influence quanti-
ties.
Table 9. Measurement Bandwidth
Parameter
Min
Typ
Max
Units
General, 50 Hz line
frequency
- high limit (-3dB)
750
Hz
- low limit (-3dB)
30
Hz
Reactive Power and
Energy, Voltage and
Current Measurement
- high limit
360
Hz
- low limit
40
Hz
Line Frequency
- high limit
350
Hz
- low limit
20
Hz
Table 10. Maximum Error
Current
Voltage
Power
Factor
Min
Typ
Max
Units
0.05I
B
U
N
1.000
-0.4
+0.4
%
0.1I
B
...I
FS
U
N
1.000
-0.2
+0.2
%
0.1I
B
U
N
0.5
lagging
-0.4
+0.4
%
0.2I
B
...I
FS
U
N
0.5
lagging
-0.4
+0.4
%
0.1I
B
U
N
0.8
leading
-0.4
+0.4
%
0.2I
B
...I
FS
U
N
0.8
leading
-0.4
+0.4
%
0.2I
B
...I
FS
U
N
0.25
lagging
-1.0
+1.0
%
Table 11. Single-phase Load Error
Current
Voltage
Power
Factor
Min
Typ
Max
Units
0.1I
B
...I
FS
U
N
1.000
-0.5
+0.5
%
0.1I
B
...I
FS
U
N
0.5
lagging
-0.5
+0.5
%
Table 12. Voltage Variation Error
Current
Voltage
Power
Factor
Min
Typ
Max
Units
0.1I
B
0.9U
N
...
1.1U
N
1.000
-0.2
+0.2
%
0.1I
B
0.9U
N
...
1.1U
N
0.5
lagging
-0.2
+0.2
%