Recommended operating conditions – Rainbow Electronics TS81102G0 User Manual
Page 10

10
TS81102G0
2105C–BDC–11/03
Note:
Absolute maximum ratings are limiting values, to be applied individually, while other parameters are within specified operating
conditions. Long exposure to maximum rating may affect device reliability. The use of a thermal heat sink is mandatory. See
“Thermal and Moisture Characteristics” on page 26.
Recommended
Operating
Conditions
Data output current
A[0…9] to H[0…9] or
RefA to RefH or
DR or DRb
Maximum current
36
mA
TTL input voltage
Clkln Type
RatioSel
NbBit
AsyncReset
BIST
GND to V
CC
V
Maximum input voltage on diode for
temperature measurement
DIODE
700
mV
Maximum input current on diode
DIODE
8
mA
Maximum junction temperature
T
j
135
°
C
Storage temperature
T
stg
-65 to 150
°
C
Table 2.
Absolute Maximum Ratings (Continued)
Parameter
Symbol
Comments
Value
Unit
Table 3.
Recommended Operating Conditions
Parameter
Symbol
Comments
Recommended Value
Min
Typ
Max
Unit
Positive supply voltage
V
CC
4.45
5
5.25
V
Positive output buffer supply
voltage
V
PLUSD
ECL output compatibility
–
0
–
V
Positive output buffer supply
voltage
V
PLUSD
PECL output compatibility
–
3.3
–
V
Positive output buffer supply
voltage
V
PLUSD
TTL output compatibility
–
3.3
–
V
Negative supply voltage
V
EE
-5.25
-5
-4.75
V
Operating temperature range
T
J
Commercial grade: “C”
Industrial grade: “V”
0 < Tc; Tj < 90
-40 < Tc; Tj < 110
°C