beautypg.com

Pin description – Rainbow Electronics MAX5961 User Manual

Page 9

background image

MAX5961

0 to 16V, Quad, Hot-Swap Controller

with 10-Bit Current and Voltage Monitor

_______________________________________________________________________________________

9

Pin Description

PIN

NAME

FUNCTION

1

SENSE1

Channel 1 Current-Sense Input. Connect SENSE1 to the source of an external MOSFET and to one end of
R

SENSE1

(see the Typical Application Circuit).

2

MON1

Channel 1 Voltage Monitoring Input

3

GATE1

Channel 1 Gate-Drive Output. Connect to gate of an external n-channel MOSFET.

4

GND1

Channel 1 Gate Discharge Current Ground Return. Connect all GND_ and DGND to AGND externally
using a star connection.

5

GND3

Channel 3 Gate Discharge Current Ground Return. Connect all GND_ and DGND to AGND externally
using a star connection.

6

GATE3

Channel 3 Gate-Drive Output. Connect to the gate of an external n-channel MOSFET.

7

MON3

Channel 3 Voltage Monitoring Input

8

SENSE3

Channel 3 Current-Sense Input. Connect SENSE3 to the source of an external MOSFET and to one end of
R

SENSE3

(see the Typical Application Circuit).

9

POL

Polarity Select Input. Connect to DREG for active-high power-good outputs (PG_). Connect to GND_ for
active-low power-good outputs.

10

DREG

Logic Power-Supply Input. Connect to REG externally through a 10

Ω resistor and to DGND with a 1µF

ceramic capacitor.

11

ON1

Channel 1 Precision Turn-On Input

12

ON3

Channel 3 Precision Turn-On Input

13

FAULT1

Channel 1 Active-Low Open-Drain Fault Output. FAULT1 goes low if an overcurrent shutdown occurs on
channel 1.

14

FAULT2

Channel 2 Active-Low Open-Drain Fault Output. FAULT2 goes low if an overcurrent shutdown occurs on
channel 2.

15

FAULT3

Channel 3 Active-Low Open-Drain Fault Output. FAULT3 goes low if an overcurrent shutdown occurs on
channel 3.

16

FAULT4

Channel 4 Active-Low Open-Drain Fault Output. FAULT4 goes low if an overcurrent shutdown occurs on
channel 4.

17

SDA

I

2

C Serial-Data Input/Output

18

SCL

I

2

C Serial-Clock Input

19

ALERT

Open-Drain Alert Output. ALERT goes low during a fault to notify the system of an impending failure.

20

PG1

Channel 1 Open-Drain Power-Good Output

21

PG2

Channel 2 Open-Drain Power-Good Output

22

PG3

Channel 3 Open-Drain Power-Good Output

23

PG4

Channel 4 Open-Drain Power-Good Output

24

DGND

Digital Ground. Connect all GND_ and DGND to AGND externally using a star connection.

25

ON4

Channel 4 Precision Turn-On Input

26

ON2

Channel 2 Precision Turn-On Input

27

RETRY

Autoretry Fault Management Input. Connect to DREG to enable autoretry operation. Connect to DGND to
enable latched-off operation.

28

I.C.

Internally Connected. Connect to AGND only.