0 to 16V, Quad, Hot-Swap Controller
with 10-Bit Current and Voltage Monitor
_______________________________________________________________________________________
9
Pin Description
PIN
NAME
FUNCTION
1
SENSE1
Channel 1 Current-Sense Input. Connect SENSE1 to the source of an external MOSFET and to one end of
R
SENSE1
(see the Typical Application Circuit).
2
MON1
Channel 1 Voltage Monitoring Input
3
GATE1
Channel 1 Gate-Drive Output. Connect to gate of an external n-channel MOSFET.
4
GND1
Channel 1 Gate Discharge Current Ground Return. Connect all GND_ and DGND to AGND externally
using a star connection.
5
GND3
Channel 3 Gate Discharge Current Ground Return. Connect all GND_ and DGND to AGND externally
using a star connection.
6
GATE3
Channel 3 Gate-Drive Output. Connect to the gate of an external n-channel MOSFET.
7
MON3
Channel 3 Voltage Monitoring Input
8
SENSE3
Channel 3 Current-Sense Input. Connect SENSE3 to the source of an external MOSFET and to one end of
R
SENSE3
(see the Typical Application Circuit).
9
POL
Polarity Select Input. Connect to DREG for active-high power-good outputs (PG_). Connect to GND_ for
active-low power-good outputs.
10
DREG
Logic Power-Supply Input. Connect to REG externally through a 10
Ω resistor and to DGND with a 1µF
ceramic capacitor.
11
ON1
Channel 1 Precision Turn-On Input
12
ON3
Channel 3 Precision Turn-On Input
13
FAULT1
Channel 1 Active-Low Open-Drain Fault Output. FAULT1 goes low if an overcurrent shutdown occurs on
channel 1.
14
FAULT2
Channel 2 Active-Low Open-Drain Fault Output. FAULT2 goes low if an overcurrent shutdown occurs on
channel 2.
15
FAULT3
Channel 3 Active-Low Open-Drain Fault Output. FAULT3 goes low if an overcurrent shutdown occurs on
channel 3.
16
FAULT4
Channel 4 Active-Low Open-Drain Fault Output. FAULT4 goes low if an overcurrent shutdown occurs on
channel 4.
17
SDA
I
2
C Serial-Data Input/Output
18
SCL
I
2
C Serial-Clock Input
19
ALERT
Open-Drain Alert Output. ALERT goes low during a fault to notify the system of an impending failure.
20
PG1
Channel 1 Open-Drain Power-Good Output
21
PG2
Channel 2 Open-Drain Power-Good Output
22
PG3
Channel 3 Open-Drain Power-Good Output
23
PG4
Channel 4 Open-Drain Power-Good Output
24
DGND
Digital Ground. Connect all GND_ and DGND to AGND externally using a star connection.
25
ON4
Channel 4 Precision Turn-On Input
26
ON2
Channel 2 Precision Turn-On Input
27
RETRY
Autoretry Fault Management Input. Connect to DREG to enable autoretry operation. Connect to DGND to
enable latched-off operation.
28
I.C.
Internally Connected. Connect to AGND only.