Table 1b. Register Address Map (General)

REGISTER

DESCRIPTION

ADDRESS

(HEX CODE)

RESET

VALUE

TABLE

mon_range

MON_ input range selection

0x30

0x00

17, 18

cbuf_chx_store

Selective enabling of individual blocks in the circular buffer

0x31

0xFF

42

ifast2slow

Current threshold ratio setting for the fast comparator vs. slow
comparator

0x5E

0xFF

5a, 5b

status0

Slow-trip and fast-trip comparators status register

0x5F

Cx00

50

status1

PROT, MODE, and ON_ inputs status register

0x60

2, 4a, 4b, 29

sense_range

ILIM_ inputs status register

0x61

6, 7a, 7b

status3

RETRY, POL, ALERT, and PG_ status register

0x62

30

fault0

Status register for undervoltage detection (warning or critical)

0x63

0x00

47

fault1

Status register for overvoltage detection (warning or critical)

0x64

0x00

48

fault2

Status register for overcurrent detection (warning)

0x65

0x00

49

pgdly

Delay setting between MON_ measurement and PG_ assertion

0x66

0x00

31a, 31b

fokey

Load register with 0xA5 to enable force-on function

0x67

0x00

46

foset

Register that enables force-on function for a channel

0x68

0x00

45

chxen

Channel enable bits

0x69

3

dgl_i

OC deglitch enable bits

0x6A

0x00

38

dgl_uv

UV deglitch enable bits

0x6B

0x00

39

dgl_ov

OV deglitch enable bits

0x6C

0x00

40

cbufrd_hibyonly

Circular buffers readout mode: 8 bit or 10 bit

0x6D

0x00

43

cbuf_dly_stop

Circular buffer stop-delay. Number of samples recorded to the
circular buffer after channel shutdown.

0x72

0x19

44

peak_log_rst

Reset control bits for peak-detection registers

0x73

0x00

36

peak_log_hold

Hold control bits for peak-detection registers

0x74

0x00

37

Table 2. Grouping Hot-Swap Channels

MODE INPUT

STATUS

MODE [1]

MODE [0]

FUNCTION

DESCRIPTION

Low

1

0

Independent

Each channel operates as an independent hot-swap controller. A fault
shutdown in one channel does not affect operation of other channels.

High

0

1

Paired

Channels 1 and 3 operate together as one pair while channels 2 and 4
operate as another pair. A fault shutdown in one channel of a pair shuts
down both channels in the pair.

Unconnected

0

0

Grouped

All channels operate as a group. A fault shutdown in one channel shuts
down all four channels.

Grouping Hot-Swap Channels

Depending on the state of the MODE input, the four-
channel MAX5961 can operate as four independent

hot-swap controllers, two pairs of controllers, or with all