beautypg.com

Table 7a. sense_range register format, Table 7b. setting current-sense range – Rainbow Electronics MAX5961 User Manual

Page 21

background image

MAX5961

0 to 16V, Quad, Hot-Swap Controller

with 10-Bit Current and Voltage Monitor

______________________________________________________________________________________

21

When an overcurrent event causes the MAX5961 to
shut down a channel, a corresponding open-drain
FAULT_ output alerts the system. Figure 3 shows the

operation and fault-management flowchart for one
channel of the MAX5961.

Table 6. Specified Current-Sense and Circuit-Breaker Threshold Ranges

ILIM_

INPUT

CURRENT-

SENSE

RANGE (mV)

SPECIFIED FAST-TRIP

THRESHOLD RANGE (mV)

FAST-TRIP/

SLOW-TRIP

RATIO (%)

SPECIFIED

SLOW-TRIP

THRESHOLD RANGE (mV)

200

5.0 to 12.5

175

5.7 to 14.3

150

6.7 to 16.7

Low

0 to 25

10 to 25

(40% to 100%)

(DAC = 0x66 to 0xFF)

125

8 to 20

200

10 to 25

175

11.5 to 28.6

150

13.3 to 33.3

High

0 to 50

20 to 50

(40% to 100%)

(DAC = 0x66 to 0xFF)

125

16 to 40

200

20 to 50

175

22.9 to 57.1

150

26.7 to 66.7

Unconnected

0 to 100

40 to 100

(40% to 100%)

(DAC = 0x66 to 0xFF)

125

32 to 80

Table 7a. sense_range Register Format

Description:

Fast-trip threshold maximum range setting bits, from ILIM_ three-state inputs

Register Title:

sense_range

Register Address:

0x61

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

Ch4_IGS1

Ch4_IGS0

Ch3_IGS1

Ch3_IGS0

Ch2_IGS1

Ch2_IGS0

Ch1_IGS1

Ch1_IGS0

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

Table 7b. Setting Current-Sense Range

ILIM_ INPUT STATE

Chx_IGS1

Chx_IGS0

MAXIMUM CURRENT-SENSE SIGNAL (mV)

Low

1

0

25

High

0

1

50

Unconnected

0

0

100

1

1