Fault Logging and Indications
The MAX5961 provides detailed information about any
fault conditions that have occurred. Independent
FAULT_ outputs specifically indicate circuit-breaker
shutdown events, while an ALERT output is asserted
whenever a problem has occurred that requires atten-
tion or interaction.
Fault Dependency
If a fault event occurs (digital UV warning/critical, digital
OV warning/critical, or digital overcurrent warning) the
fault is logged by setting a corresponding bit in regis-
ters fault0, fault1, or fault2 (see Tables 47, 48, and 49).
Likewise, circuit-breaker shutdown events are logged in
register status0[7:0] (see Table 50).
Table 45. Force-On Control Register Format
Description:
Force-on control register
Register Title:
foset
Register Address:
0x68
R
R
R
R
R/W
R/W
R/W
R/W
RESET
VALUE
0
0
0
0
ch4_fo
ch3_fo
ch2_fo
ch1_fo
0x00
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Table 46. Force-On Key Register Format
Description:
Force-on key register (must contain 0xA5 to unlock force-on feature)
Register Title:
fokey
Register Address:
0x67
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
RESET
VALUE
fokey[7]
fokey[6]
fokey[5]
fokey[4]
fokey[3]
fokey[2]
fokey[1]
fokey[0]
0x00
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Table 47. Undervoltage Status Register Format
Description:
Undervoltage digital-compare status register (warning [3:0] and critical [7:4] undervoltage event
detection status)
Register Title:
fault0
Register Address:
0x63
R/C
R/C
R/C
R/C
R/C
R/C
R/C
R/C
RESET
VALUE
ch4_uv2
ch3_uv2
ch2_uv2
ch1_uv2
ch4_uv1
ch3_uv1
ch2_uv1
ch1_uv1
0x00
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0