Voyager User’s Manual - MASTER Mode
Page 65
Voyager User’s Manual - MASTER Mode
Here are the Master Mode functions:
MIDI RUN STATUS
The MIDI RUN STATUS (MIDI Running Status) function is used to reduce
the MIDI data sent when a number of MIDI messages with the same
Status Byte are sent. When enabled, the Running Status function eliminates
the Status Byte. Some MIDI devices can handle MIDI Running Status and
some can’t, so you have an option of turning this on (‘YES’) or off (‘NO’).
To change the setting, use the CURSOR to highlight the desired choice
and press ENTER.
MIDI LOCAL CONT. (Keyboard editions only)
The MIDI LOCAL CONTROL menu provides Local ON/OFF control
of seven Voyager functions: Pitch Bend Wheel (PBwhl), Mod Wheel
(Modwhl), Aftertouch (Press), Panel Knobs (Pots), Panel Switches (Swtch),
and Touch Surface (T.S.). An eighth selection (All), allows you to switch the
Local control of all seven functions at once. To change the status of any
Voyager control function, use the CURSOR to make a selection and press
the +1/-1 buttons to select ON/OFF. When all changes have been made,
press ENTER to enter the changes. To escape at any time without changes,
press MASTER.
When Local Control of any interface is switched OFF, the Voyager will
display a ‘Local Controls’ message upon power-up, showing the status of all
controls. To dismiss the message, press any button.
When Local Control of Pots or Switches is set to OFF, and the Voyager
is set to display parameter values, the LCD will display a ‘LOCAL OFF’
message when you adjust those controls. For example, if Local Control
of Pots has been switched OFF and you then adjust the Mod Wheel Buss
AMOUNT control (or any other Pot), the Voyager’s LCD will include a