VEGA VEGAMET 514… D User Manual
Page 9
VEGAMET 514… D
9
Indicating element
Clear text indication
LC-display
- 4 line, 6 figures each
- background lightning
Analog indication
11 segments 0 % … 100 %
acc. to MST-enquiry
- %-value of level
- %-value of flow
LED in front plate
green on: operating voltage on
red: fault signal
yellow (per relay): relay switching condition
Operating elements
Front plate
6 keys for configuration and parameter adjustment
Ambient conditions
Permissible ambient temperature
-20
°
C … +60
°
C
Storage and transport temperature
-40
°
C … +80
°
C
Electrical connection
Multipoint connector component
acc. to DIN 41 612, series F, 36-pole (three row) d, b, z
(partly equipped)
Carrier BGT 596 (Ex)
connection to the respective module
Housing type 505
connection to screw terminals (max. 2,5 mm
2
)
Electrical protective measures
Protection
- unassembled
IP 00
- mounted into
carrier BGT 596
front side completely equipped: IP 40
upper and lower side: IP 20
wiring side: IP 00
- mounted into housing
- terminal housing
IP 20
- housing general
IP 30
Protection
II (in housing type 505 or type 506)
Overvoltage category
II
Electrical separating measures
Reliable separation acc. to VDE 0106,
part 1
between power supply, fail safe and level relay,
meas. data inputs and correction inputs
- limit voltage
250 V
- isolation resistance
2,3 kV
Galvanic separation
between relay outputs
- limit voltage
250 V
- isolation resistance
1,4 kV
Potential separation
between DISBUS, transistor outputs and correction
inputs
- limit voltage
50 V
- isolation resistance
0,5 kV
Common reference potential at
voltage/current outputs, correction inputs
Product description
>>