VEGA VEGAMET 514… D User Manual
Page 8
8
VEGAMET 514… D
Product description
Current output
Number
3 outputs
Function
current output 2 and 3 can be configured and
parameter adjusted as:
- level proportional
- flow proportional
- flow pulses
- sampling pulse
Output values
- level / flow proportional
Load
max. 500
Ω
Range
0/4 … 20 mA
Resolution
0,05 % of range
Linearity error
0,05 % of range
Temperature error
0,05 %/10 k of range
- pulse output
Load
min. 600
Ω
Voltage pulse
12 V DC at 20 mA
Pulse length
200 ms
Voltage output
Number
3 outputs
Function
analog output of the output results
Range
0/2 … 10 V
Current
max. 1 mA
Resolution
0,05 % of range
Linearity error
0,05 % of range
Temperature error
0,06 %/10 k of range
Relay outputs
Number
2 switching relays
1 fail dafe relay
Function
can be configured and parameter adjusted as:
- switching relay for level or flow
- pulse relay-flow quantity
- pulse relay-sampling
Contact
1 floating spdt
AgNiO and hard gold plated
Turn-on voltage
min. 10 mV DC
max. 250 V AC/DC
Switching current
min. 10
µ
A
max. 3 A AC, 1 A DC
Breaking capacity
max. 500 VA, 54 W
Min. switching hysteresis (Low/High-Delta)
0,5 %
DISBUS-output
Function
digital transmission of output results and
system information to VEGADIS 174 or
VEGACOM 557
Connection line
2-wire
Line length
max. 1000 m
>>