VEGAMET 514… D
31
Rectangular overflow without contraction
With sharp overflow edge and throat
Set-up, parameter adjustment
Values for Q
max
B
Q
max
h
max
Q
min
h
min
in mm
in m
3
/h
in mm
in m
3
/h in mm
200
52,3
120
18,5
60
300
109,6
150
27,7
60
400
295,8
240
37,0
60
500
441,2
270
46,2
60
600
620
300
55,5
60
800
1519
450
73,9
60
1000
2923
600
92,4
60
1500
6128
750
138,7
60
2000
13535
1050
184,9
60
3000
34666
1500
277,3
60
Calculation of Q
max
The following formula can be used for calculation of
the actual flow of liquid levels < h
max
… h
min
.
Presumed values for a calculation example
B = 0,4 m
K = 6290
h = 0,13 m
Q
max
= B x K x h
1,5
= 0,4 x 6290 x 0,13
1,5
= 117,9 m
3
/h
Rectangular flume (V-Notch)
With sharp overflow edge
Values for Q
max
α
K
Q
max
h
max
Q
min
h
min
in
°
(Factor)
in m
3
/h in mm
in m
3
/h in mm
90
4966
1385,0 600
4,4
60
60
2869
800,0
600
2,5
60
45
2056
573,3
600
1,8
60
30
1334
372,0
600
1,2
60
22,5
989
275,8
600
0,87
60
Calculation of Q
max
The following formula can be used for calculation of
the actual flow of liquid levels < h
max
… h
min
.
Presumed values for a calculation example
α
= 45
°
K = 2056 (derived from
α
)
h = 0,33 m
Q
max
= K x h
2,5
= 2056 x 0,33
2,5
= 128,6 m
3
/h
B
h
max
K = 6290
h
max
α
>>
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)