beautypg.com

Veris Technologies MSP EC and pH (1997-2008 CF card drive 1.10M) - Operating Instructions User Manual

Page 41

background image

Veris Technologies

Pub. #OM MSP03-1

41







Wash System
If wash water develops algae, flush and fill tanks with tap water; clean any algae or other foreign
matter out of tank using clean-out ball valve (right side). Set wash system ball valve (left side) to
open position, allowing water to flow to pumps. Clean filter at least once per week of operation.
Remove plug and turn on ball valve to clean.

When temperatures are dipping below freezing, prevent freeze damage to the wash system as
follows: close ball valve between tank and pumps, open up check diaphragms and drain, disconnect
quick couplers and run pumps until empty. If unit is to be left outside for long periods of time over
winter, it is advisable to add RV antifreeze to tank and run pumps for a couple of minutes to fill all
lines with anti-freeze. Purge system of anti-freeze before collecting any pH data.



• Pinch point hazard: to prevent injury, stand clear when raising or lowering any part of the
Veris MSP. Disengage automatic cycling function before working around unit. Install all
transport locks before transporting or working underneath.

Wear Item Replacement
Inspect cutting shoe for wear and gouges, replace as needed. Knock old shoe off with punch and tap
new shoe on, as shown here.

open check
diaphragm
and drain
water in line to
prevent freeze
damage

Leave BNC cover on
whenever unit is outdoors.

ball valve on

plug removed


tank clean-out
ball valve