beautypg.com

Veris Technologies MSP EC and pH (1997-2008 CF card drive 1.10M) - Operating Instructions User Manual

Page 29

background image

Veris Technologies

Pub. #OM MSP03-1

29

4. Insert pH electrodes into electrode holder. Finger-tighten plastic screws. Install BNC cover

on external controller to keep moisture out of BNC connectors. Leave BNC cover on
whenever unit is outdoors.

5. Row cleaner/firming wheel (if equipped): Pull MSP forward and check depth of row cleaner

and firming wheel. Cleaner should be clearing residue ahead of sampling shoe, but not
gouging into soil. Adjust height of cleaner relative to firming wheel by removing adjustment
pin and re-positioning disk attachment.

6. Closing disks (if equipped): Adjust closing disks as needed to properly close trench and bring

residue over row-cleaned zone. Do not operate these deeper in soil than necessary.

Closing Disks
depth adjustment
pin

Closing Disks
angle
adjustments

When wash jets are
properly aligned,
overspray is
minimized and water
bubbles out top of
electrode holder as
shown here.



Adjust height of cleaner relative
to firming wheel by removing
adjustment pin and re-
positioning disk attachment.

When installing BNC cover, route
electrode wires under box; center
box on white pad, and tighten
wingnut finger tight. Keep cover
installed even when electrodes
are removed.