an upper and lower grease zerk. Due to the limited motion of the
rockshaft, these should be lubricated on 40-hour intervals. This may
vary based on the number of times the unit is raised and lowered.
Rachet jack --
20 hour intervals
Electrode coulters
Pivot --
In all but the most extremely rocky conditions, the coulter electrodes should
not flex in the field, thus minimal movement will be realized at the pivot.
80-hour intervals should be sufficient.
Hubs --
Use good quality wheel bearing or lithium grease for lubrication, but we
suggest that you grease the hubs sparingly. Over-lubricating the hub
will result in pre-mature seal failure, and an excessive amount of grease
in the hub cap/commutator. On an interval of 150 hours, 1-2 strokes of
grease should be sufficient.
Pivot grease
zerks (2 per
hangar; 4 total )
grease zerks
grease zerk