Technical data, Differential pressure and t, Time versions and options (extract) – M&C TechGroup SP2500-H_C_I_BB_F Data sheet User Manual
Page 2
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.4
Technical Data
Technical specifications and illustrations are without
obligation, subject to modifications. 03.03/06.06
Gas Sample Probe Version
SP2500-H
SP2500-H/C/I/BB
SP2500-H/C/I/BB/F
Part No.
20S3510
20S3520
20S3530
Integrated backflush
no
via filter chamber
via filter element
Protective cover
yes
Terminal box
IP54 EN60529
Filter housing material
Stainless steeel 316 / 316Ti*
Sealing materials
FPM*
Probe flange sealing material
Novapress
Insitu probe tube/prefilter
Optional
Sample pressure max.
0,4-6 bar* abs.
Ambient temperature
-20 °C to +60 °C*** /PT100, /Fe-CuNi, /Ni-CrNi** = -20°C to +80°C
Filter chamber volume
280 cm
3
Filter element, porosity
S-2K150= Ceramic*, 2micron, /F-0, 1GF150= Glass fibre**, 0,1 micron, /FW= Spun glass**
Thermostat, Temperature adjustment
0-180°C* /PT100** /Fe-CuNi** /Ni-CrNi**
Ready for operation
after 40min
Low temperature alarm contact
Change-over contact Contact rating: 250V, 3A~, 0,25A= Alarm point: ∆T 30°C
Sample gas outlet connection
1x 1/4“ NPTi* tube connectors ø 6, 8 or 10 mm**
Backflush/Test gas connection
1/4“ NPTi* /C**= tube ø 8mm
backflush: tube Ø 8mm, span: tube Ø 6mm
Shut off valve connection /I
1/8” NPT i
Pressure range contol air /I
3 - 10 bar
Power supply
230V 50/60 Hz, 800W /115V** = 115V 60Hz, 800W (fuse protection 10A)
Electrical connections
Terminals max. 4mm
2
, 2x PG 13,5 cable gland
Electrical equipment standard
EN 61010, EN 60519-1
Mounting flange
DN65 PN6-B, SS316Ti* >DN or ANSI possible**
Weight
17kg*
*
Standard
**
Options
*** In case of higher ambient temperatures use option PT100 (Part No. 20S9025) or thermocouple Fe-CuNi respectively Ni-CrNi (Part No. 20S9027 resp.
20S9028) instead of the thermostate controller. Then, an additional electronic temperature controller (see data sheet 2-5.1) is necessary.
∆P and T90 at flow of:
100
200
500
1000
1500
Nl/hr
∆P with new filter element S-2K150/GF150
0,007
0,011
0,02
0,035
0,040
bar
T90-time for SP2500-H.. without tube
8
5,5
3
1
0,5
s
Differential pressure and T
90
-time
Versions and options (extract)
Executions
Data s.
Version
Part-No.
Basic execution, heated to 0-180 °C ,with weather protection shield, material SS 316Ti
2-1.1.5
SP2500-H
20 S 3510
Basic execution, heated to 0-180 °C ,with weather protection shield, material SS 316Ti
2-1.1.5
SP2500-H/C/I/BB
20 S 3520
Basic execution, heated to 0-180 °C ,with weather protection shield, material SS 316Ti
2-1.1.5
SP2500-H/C/I/BB/F
20 S 3530
Options (Extract)
Execution with power supply 115V/60Hz
/115V
20 S 9030
Execution with second outlet for sample gas 1/4" NPTi*
/2x*
20 S 9015
Execution with back purge/calibration gas valve, opening pressure 0,7 bar, pipe 8 mm o.d.*
/C*
20 S 9435
Execution with fiber glass filter element 0,1GF150, filter porosity 0,1 µm, sealing PTFE
/GF150
20 S 9020
Execution with spec. filter housing lid and unscrewed cartridge
incl. spun glass filling, sealing FPM, Novapress
/FW
20 S 9047
Execution with with PT00 sensor instead of the thermostat, without temp. controller
/PT100
20 S 9025
Execution with thermoelement FE-CuNi ( type J) instead of thermostat, without temp. controller
/Fe-CuN
20 S 9027
Execution with thermoelement Ni-CrNi (type K) instead of thermostat, without temp. controller
/Ni-CrNi
20 S 9028
Execution with second PT100 sensor
/2-PT100
20 S 9026
Execution with special adapter flange size DN..PN6 or ANSI..150 lbs
/DN
20 S 9004
Supporting adapter type SP2500H/SA500 to support long probe tubes and prefilters with extension tube,
including flange gasket, material 1.4571
/SA500
20 S 9433
Execution with gas pre-heater GVW1, material SS304
2-1.2.5
/GVW1
20 S 9058
Execution with connection of the gas pre-heater to valve ”BB” and to gas inlet
2-1.2.5
/GVW
20 S 9062
Execution with steam heating, without controller and valves
/D
20 S 9033
* only SP2500-H