M&C TechGroup FM-200K-H Data sheet User Manual

Flowmeter series fm, Special features, Application

background image

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

9.3

Embracing Challenge

ƒ

ƒ

Heatable version, max 180 °C

ƒ

ƒ

Electrically heated version, max.
180 °C

ƒ

ƒ

Needle valve integrated in the inlet

ƒ

ƒ

Large scaling

ƒ

ƒ

Sure connection technique

ƒ

ƒ

No cold bridges

ƒ

ƒ

Integrated thermostat

ƒ

ƒ

Status contact output

ƒ

ƒ

Easy to maintain

ƒ

ƒ

Optional with flow alarm FA...

Special Features

Flowmeter series FM®

Heatable up to 180 °C Version FM-2K
Electrically heated up to 180 °C,
with needle valve at the inlet
Version FM-200K-H

FM-200K-H

Application

The M&C flowmeters FM-2K and FM-200K-H

are used in analysis technique to

control gas flow up to an operating tempera-

ture of 180 °C.
Depending on the flowmeter glass tube and

the floating ball out of glass, ranges from 16

l/h to 800 l/h can be realized.

Description

The M&C flowmeters FM-2K and FM-200K-H

consist of a vertical cone shaped glass tube

with a free movable float ball inside. The

sample gas, flowing from the bottom to the

top, lifts the float ball as far as an annular gap

appears between the tube wall and the float

ball and the forces on the ball are compen-

sated. The position of the float ball is related

to a scale on the flow meter tube.
The FM-2K is a basic heat resistant ver-

sion for installation in heated systems.

The electrically heated version FM-200K-H is

equipped with an integrated needle valve

and is fixed on a mounting plate, decoupled

from heat and covered with an insulated

enclosure. The heater consists of a heating

element with high capacity. The temperature

is adjustable on the integrated thermostat up

to 180 °C with high temperature limiter and

low temperature alarm.
The window of the heat insulated enclosure

guarantees a proper reading-out. The electri-

cal connection box with integrated thermo-

stat is installed outside the enclosure on the

mounting plate. A flow control is possible

consisting of fibre-optical light guides FO1,

the sensor head FA2-H and the pre-amplifier

K-FA-H which is installed on the mounting

plate as well. The electronic controller FA-1..

(option) has to be mounted externally. – See

data sheet 9.5 –
In order to avoid cold bridges, the connect-

ing fittings are equally heated by means of

double-ended thermal conducting jaws. The

electrically heated sample lines type 3/4/5-

N/M/H – see data sheet 3.1 – are fixed with

mounting brackets.