Technical data – M&C TechGroup MP-F10_R Data sheet User Manual
Page 3
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
10.9
Bellows pump
MP-F05
MP-F05/R
MP-F10
MP-F10/R
Integrated needle valve
no
yes
no
yes
Part No. 230V 50Hz
05 P 1000
05 P 1010
05 P 1005
05 P 1015
Part No. 115V 60Hz
05 P 1000a
05 P 1015a
05 P 1005a
05 P 1015a
Degree of protection
IP 55
EN 60529
Capacity max.
320 Nl/hr without pressure
600 Nl/hr without pressure
Operating pressure
max. 0,4 - 2,2 bar abs.
max. 0,2 - 3,2 bar abs.
Sample temperature
-30 to +140 °C
Ambient temperature
+10 to +40 °C / 0 to +40 °C for dry sample gas
Storage temperature
-15 to +60 °C
Current consumption 230V/115V
0,95A/1,8A
Power consumption
90W
cos φ
230V : 0,94 / 115V : 0,98
Gas connections
G1/4" i DIN ISO 228/1
Material of sample
contacting parts
PTFE, PFA, FEP, (+PVDF for type /R)
Operating mode
100% continous duty, start of the pump only without pressure
Electrical equipment standard
EN 60204-1
Weight
4,7 Kg
Options
05 P 1050
Mounting bracket with 4 anti-vibration pads for bellows pump MP-F
05 P 1060
Extra charge for upper pump head of bellows pump MP-F out of stainless steel
05 P 1070
Extra charge for upper pump head of bellows pump MP-F../R out of stainless steel with needle valve out of PVDF
Technical Data
Technical specifications and illustrations are without
obligation, subject to modifications. 09.96/11.06