beautypg.com

Flow monitoring fa1-h-.. on flowmeter fm1-h, Technical data – M&C TechGroup FA1-H-.. Data sheet User Manual

Page 2

background image

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

9.6

Technical specifications and illustrations are without

obligation, subject to modifications. 12.97/11.06

2

FO...

FA2-H

4

3

2

1

FA-...

K-FA-H

FA2-H

heated

FM1-H

K-FA-H

Flow monitoring FA1-H-.. on flowmeter FM1-H

1 piece sensor head FA2-H

2 pieces light guides FO1/FO2/FO3 for monostable function

1 piece K-FA-H pre-amplifier

1 piece electronic controller FA-1.1 or FA-1.4

(* Other mounting designs for the light guides on request.)

Reversing power consumption 230V 50/60Hz / 115V 50/60Hz, adjusted at works: 230V 50/60Hz

Technical data: see data sheet FA-1.1.., FA-1.4, K-FA 5-6.10.2

Technical Data

Electronic controller

FA-1.1

FA-1.4

Part No. 230V 50/60Hz

02 E 7300*

02 E 7110

Part No. 115V 50/60Hz

02 E 7300*

02 E 7110 a

Part No. 24V

DC

02 E 7300 d

02 E 7110 d

Part No. 24V

AC

02 E 7300 b

02 E 7110 d

Sensor Head FA2-H*

Light guide FO1

Light guide FO3

Light guide FO2

pre-amplifier K-FA-H

Part Number

02 E 4002

02 E 4060

02 E 4063

02 E 4065

02 E 4010

Function monostable

1x

2 pieces

1x

Measuring tube

5-14 mm

Light guide length

600 mm

900 mm

1200 mm

Dimensions W x D x H

24 x 40 x 24

ø 6 mm

80 x 160 x 55

Weight

90 g

230 g

330 g

420 g

560 g

Material

anodized aluminium

Glass fibre, SS 316Ti, brass-chromed

Polycarbonate

Assembly

Fixed with clamping screw

Wall mounting

Cable entry

terminal range 5mm - 10mm

Electrical connection

Terminals 2,5 mm

2

Supply voltage

12V

DC

internal from FA-1..

Electrical standard

EN61010

Operating temperature

- 25 °C to +180 °C

-25 °C to +60 °C

Storage temperature

- 25 °C to +70 °C

System of protection

IP65 EN 60529

Complete flow monitoring unit

Type
Part Number

FA1-H-6
02 E 4270

FA1-H-9
02 E 4273

FA1-H-12
02 E 4275

consisting of :
Sensor FA2-H

(02 E 4002)

1 piece

Light guide FO1, 600 mm long

(02 E 4060)

2 pieces

Light guide FO3, 900 mm long

(02 E 4063)

2 pieces

Light guide FO2, 1200 mm lang

(02 E 4065)

2 pieces

Pre-amplifier with adapter K-FA-H

(02 E 4010)

1 piece

Electronic controller FA-1.1 / 230V/115V

(02 E 7300)

1 piece

Separate electronic controller required for the K-FA-H pre-amplifier

Complete flow monitoring unit FA1-H-.. :