M&C TechGroup L_PV-1 Series Data sheet User Manual
Page 3
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
11.1
Technical specifications and illustrations are without
obligation, subject to modifications. 08.98/11.06
Ball valves series L
type 2L/PV1
type 3L/PV1
type 4L/PV1
type 5L/PV1
Contact /K
Part No.
01V3000
01V3050
01V3100
01V3150
01V2005
Ball hole
l-form
L-form vertical
2x L-form
L-form vertical
Nominal width
NW 4*
Max. operating pressure at 20 °C
PN10, 10 bar
Flow coefficient
0,43*
Operating- and ambient temperature
-20 up to +80 °C*
-10 up to +60 °C
Storage temperature
-30 up to +110 °C
-25 up to +70 °C
Operation
manual
manual
Type of mounting
front plate
option for wall mounting: mounting angles as /K, part no.:
01V2006 01V2004 01V2006 01V2004
wall mounting
Material of sample contacting parts
PVDF, FPM*
Connections G1/4" i DIN ISO 228/1*
2x
3x
4x
5x
Controlled position
1x
Electrical connection
terminals 3 x 4 mm
2
Protection
IP20 EN 60529
Max. contact rating of change over contact
48V, 0,5A, 24W
Weight
0,07 kg
0,08 kg
0,09 kg
0,1 kg
0,14 kg
* Standard version ex stock; other structural shape, material, nominal width or connections upon request.
The max. operation pressure decreases with increasing temperature.
The temperature of 20 °C is related to air at 65% humidity (DIN 50014).
Max. operation pressure depending on the operation temperature
Technical Data
ba
r
0
5
10
15
20
25
30
35
40
45
50
0
1
2
3
4
5
6
7
55
60
65
70
75
80
85
90
95
8
9
10
100 °C
PVDF