Gas Conditioning Unit series PSS®

version PSS-10/1

Part No. for 230V 50Hz version

01G5000

Part No. for 115V 60Hz version

01G5000a

Sample outlet dew point

range of adjustment: +2 °C ..... +15 °C, factory setting: +5 °C

Dew point stability

at constant conditions < ±0,1 °C

Sample inlet temperature

**max. 80 °C optional: **max.180 °C with stainless steel bulkhead union

Sample inlet dew point

**max.+80 °C

Gas flow rate

**max. 480 Nl/hr

Ambient temperature

**+5 °C up to +40 °C

Storage temperature

-25 °C up to +65 °C

Pressure

0,7 bar up to 1,4 bar abs.

Total cooling capacity

**max. 80 kJ/hr

Number of gas inlets

1

Number of gas outlets

1 optional: max. 4

Medium connections

tube connection 4/6 mm

Material of sample contacting parts

stainless steel, glass, PVDF, Viton

®

, Novoprene

®

Ready for operation

approx. 10 min.

Power supply

230V 50Hz or 115V 60Hz

Power consumption

max. 350VA; with option temperature controller and heated sample line 230V: max.1730VA 115V:max. 1040VA

Fuse protection

4A t, 5x 20 mm, with option temperature controller: 6,3A t

Electrical connection

Cold appliance plug with 2 m of cable

Case protection

IP20 (DIN 40050. IEC 529)

Housing

portable aluminium-frame case

Housing dimensions

555 mm x 460 mm x 290 mm (H x W x D)

Electrical equipment standard

EN61010

Weight

approx. 24 kg

Options

Type

Part No.

Further sample gas outlet

Parallel samplegas outlet, tubing via T-piece on lateral PVDF bulkhead fitting, DN4/6,
max. 4 pieces

01G9065

Flowmeter, max. 4 pieces

FM40 7-70 l/hr air, mounted in sample gas outlet
FM40 15-150 l/hr air , mounted in sample gas outlet
FM40 25-250 l/hr air , mounted in sample gas outlet
FM40 50-500 l/hr air, mounted in sample gas outlet

01G9070
01G9075
01G9080
01G9085

Fittings out of PVDF

Fittings out of PVDF instead of PP and 3m FPM sample tube DN4/6

01G9025

Sample tube

Sample tube out of Kanthal

®

ø 6 mm, length 1 m, sampling temperature max. 1300 °C

01G9030

Liquid alarm

Liquid alarm LA 1/1.4, consisting of: liquid alarm sensor LA1, controller LA1.4, filter glass
F120G-D with GL connection incl. mountage/wiring. In case of condensate inrush,
the sample gas pump is automatically switched of.

01G9035

3-way ball valve

3L/PV-1 for switching over from test gas to sample gas, in the inlet of the sample gas
conditioning unit, mounted with mounting brackets, fitting PVDF

01G9046

5-way ball valve

5L/PV-1 for switching over from test gas to sample gas, in the inlet of the sample gas
conditioning unit, mounted with mounting brackets, fitting PVDF

01G9045

Electronic temperature con-
troller for max. 12 m
heated sample line 100W/m

701 control range 0-200 °C, inlet PT100, power 230V 50Hz,
Contact capacity 250V

AC

max. 4A, completely mounted incl.

7-pin plug 10A

01G9055

Electronic temperature con-
troller for max. 12 m
heated sample line 100W/m

701 control range 0-200 °C, inlet PT100, power 115V 60Hz,
Contact capacity 250V

AC

max. 4A, completely mounted incl. 7-pin plug 10A

01G9055a

Connecting adapter DN4/6 for
heated sample line

PSS-10 connecting adapter with bending protection for rigid mountage
of heated sample line with interchangeable PTFE tube DN4/6, consisting of
stiffening plate, Swagelok fitting with 4mm cartridge, material: SS316Ti.

01G9062

Connecting adapter DN6/8 for
heated sample line

PSS-10 connecting adapter with bending protection for rigid mountage
of heated sample line with interchangeable PTFE tube DN6/8, consisting of
stiffening Swagelok fitting with 4mm cartridge, material: SS316Ti.

01G9063

Technical Data

PP

= Polypropylene

PTFE = Polytetrafluoroethylene (Teflon

®

)

PVDF = Polyvinylidenfluoride

**

Maximum values in technical data’s must be rated in consideration of total cooling capacity at 25 °C ambient temperature and 5 °C outlet dew point.

Other versions on request.