M&C TechGroup ECP3000 Data sheet User Manual

Peltier-gas cooler series ecp, Special features, Application

background image

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

6.1

Embracing Challenge

ƒ

ƒ

With Jet-Stream heat exchanger avail-
able in three standard materials

ƒ

ƒ

Ambient temperature up to +50 °C

ƒ

ƒ

Outlet dew point adjustable from +2 °C
to +15 °C

ƒ

ƒ

Dew point stability ± 0,1 °C

ƒ

ƒ

With Alarm contact

ƒ

ƒ

Small dimensions, light-weight

ƒ

ƒ

Optimum reliability

ƒ

ƒ

Self-controlling

Special Features

Peltier-Gas Cooler Series ECP®

Version ECP1000 with 1x 150 Nl/h
Version ECP2000 with 2x 150 Nl/h
Version ECP3000 with 1x 350 Nl/h

ECP 1000-G

Application

ECP gas coolers are used in gas analy-

sis to lower the dew point of humid to

avoid condensate in the analyser. An extreme-

ly stabel gas dew point avoids water vapour

crosssensitivity and volumetric errors.

Description

The electronically controlled peltier cooler

produced by M&C incorporates the “Jet-

Stream” design of heat exchanger. This

design induces condensate formation and

guarantees optimum dew point reduction

to a stable low value, eliminating the need for

additional pre-drainage devices.
The condensate formed should be

removed with a small peristaltic pump,

simple trap or collection vessel. The sim-

ple construction employed enables heat

exchanges of different materials to be used

depending on the application.
The operating status of the cooler is dis-

played by three LED indicators, one each

for over or under temperature alarm and

one which pulsates showing the cooler

is functioning correctly. The alarm status

changes when the temperature deviates by

± 3 °C from the set point.
The compact lightweight design of this

device makes it ideal for use in portable

and compact continous sample conditioning

systems.

Technical specifications and illustrations are without

obligation, subject to modifications. 10.96/06.06

Application example for ECP

1

Heated filter sample probe SP210-H or SP2000-H

2

Heated sample line 4M4/6

3

Cooler ECP1000

4

3-way ball valve 3L/PV-1

5

Peristaltic pump SR25.2

6

Diaphragm pump MP47 or MP06/12 or N5KP

7

Fine filter FP-2T-D with liquid alarm LA1

8

Aerosol filter CLF-5 /W optional according to application

9

Flow meter FM10 or FM40, 25-250 Nl/hr

10 Analysers f. e. PMA100

8

Alternative:

trap with float or condensate

collection vessel

5

condensate OUT

+5°C

4

3

10

9

7

ECP

1

2

sample gas IN

test gas

IN

6