Embracing Challenge
Sampling of dust loaded process gases
Small volume, fast response time
Easy mounting and maintenance
Self-regulated electrical heating
Alarm contact for low temperature
With new isolation cover for outdoor
mounting
Test gas connection according to
EN14181 for test gas feeding via filter
element available as standard
Insitu probe tube optional
Special Features
Gas Sample Probe Series SP®
Electrically heated, compact version with weather protection
cover and test gas connection as standard
SP180-H
SP180-H
Application
The M&C gas sample probe version
SP180-H is applicable for continuous gas
sampling. The compact design requires
only limited space. The gas sample probe
is equipped with a new protective cover
and thus also suitable for outdoor mounting.
Description
The design of the M&C probe version SP180-H
guarantees simple mounting, safe operation
and problem-free maintenance.
Changing the external filter element needs
no tools and no disassembling of the sample
line. For the change of the filter element the
complete filter assembly is removed out of
the probe head. Easy checkup of the filter
element and the gaskets, cleaning the filter
area of the probe head respectively the insitu
probe tube without dismounting the sample
probe are only a few advantages of the M&C
probe.
In the heated filter housing out of stainless
steel the 2 micron ceramic filter element is
located. More filter element materials are
available as option. The compact design
and the new all-round heat insulation and
weather protection ensures an optimized
heat distribution as well as safe operation
without dew point lower deviation in the filter
or flange area.
The heating of the gas sample probe to 180°C
happens with special self-regulated heating
elements within a range of 110V to 240V wit-
hout switching.
No temperature controller respectively tem-
perature limitation is necessary. The sepa-
The sepa-
rate thermo switch enables a low tempera-
ture monitoring (<160 °C, NO). For electrical
connection a junction box with terminals is
mounted.
The gas sample probe SP180-H has a calibra-
tion gas connection as standard according to
EN14181 (regulation for calibration of emissi-
on monitoring systems) that enables calibra-
tion gas feeding via the filter element of the
gas sample probe.
The stainless steel insitu probe tube SP210/
SS (option) is screwed into the DN65 PN6
mounting flange. The maximum operating
temperature of the tube out of stainless steel
is 600 °C.
For long and cold connection pieces or for
dew point lower deviations in the process
the heated probe tubes SP30-H or SP35-H are
used (see 2.15).
For solution of specific sampling problems
you can find more filter elements, probe
tubes and pre-filters in our wide range of M&C
probe accessories (see 2.14 and 2.17).
Technical specifications and illustrations are without