ƒ

Sampling of dust loaded process gases

ƒ

ƒ

Small volume, fast response time

ƒ

ƒ

Easy mounting and maintenance

ƒ

ƒ

Self-regulated electrical heating

ƒ

ƒ

Alarm contact for low temperature

ƒ

ƒ

With new isolation cover for outdoor
mounting

ƒ

ƒ

Test gas connection according to
EN14181 for test gas feeding via filter
element available as standard

ƒ

ƒ

Insitu probe tube optional

Special Features

Gas Sample Probe Series SP®

Electrically heated, compact version with weather protection
cover and test gas connection as standard
SP180-H

SP180-H

Application

The M&C gas sample probe version

SP180-H is applicable for continuous gas

sampling. The compact design requires

only limited space. The gas sample probe

is equipped with a new protective cover

and thus also suitable for outdoor mounting.

Description

The design of the M&C probe version SP180-H

guarantees simple mounting, safe operation

and problem-free maintenance.

Changing the external filter element needs

no tools and no disassembling of the sample

line. For the change of the filter element the

complete filter assembly is removed out of

the probe head. Easy checkup of the filter

element and the gaskets, cleaning the filter

area of the probe head respectively the insitu

probe tube without dismounting the sample

probe are only a few advantages of the M&C

probe.

In the heated filter housing out of stainless

steel the 2 micron ceramic filter element is

located. More filter element materials are

available as option. The compact design

and the new all-round heat insulation and

weather protection ensures an optimized

heat distribution as well as safe operation

without dew point lower deviation in the filter

or flange area.

The heating of the gas sample probe to 180°C

happens with special self-regulated heating

elements within a range of 110V to 240V wit-

hout switching.

No temperature controller respectively tem-

perature limitation is necessary. The sepa-

The sepa-

rate thermo switch enables a low tempera-

ture monitoring (<160 °C, NO). For electrical

connection a junction box with terminals is

mounted.

The gas sample probe SP180-H has a calibra-

tion gas connection as standard according to

EN14181 (regulation for calibration of emissi-

on monitoring systems) that enables calibra-

tion gas feeding via the filter element of the

gas sample probe.

The stainless steel insitu probe tube SP210/

SS (option) is screwed into the DN65 PN6

mounting flange. The maximum operating

temperature of the tube out of stainless steel

is 600 °C.

For long and cold connection pieces or for

dew point lower deviations in the process

the heated probe tubes SP30-H or SP35-H are

used (see 2.15).

For solution of specific sampling problems

you can find more filter elements, probe

tubes and pre-filters in our wide range of M&C

probe accessories (see 2.14 and 2.17).

Technical specifications and illustrations are without
obligation, subject to modifications. 07.13