Read auto pps – ACS ACR1283L User Manual
Page 40
![background image](/manuals/248162/40/background.png)
ACR1283L – Reference Manual
Version 1.00
www.acs.com.hk
Page 40 of 55
5.4.9.
Read Auto PPS
This command is used to check current auto PPS setting.
Read Auto PPS Format (5 Bytes)
Command
Class
INS
P1
P2
Lc
Read Auto
PPS
0xE0h
0x00h
0x00h 0x24h
0x00h
Set Auto PPS Response Format (9 Bytes)
Response Class
INS
P1
P2
Le
Data Out
Result
0xE1h 0x00h 0x00h 0x00h 0x02h
Max Speed
Current Speed
Where:
Max Speed (1 Byte):
Maximum Speed
Current Speed (1 Byte): Current Speed
Value can be: 106k bps = 0x00h (equal to No Auto PPS)
212k bps = 0x01h
424k bps = 0x02h (default setting)
848k bps = 0x03h