integer (4 bytes).
Example 1: Decimal –4 = {0xFFh, 0xFFh, 0xFFh, 0xFCh}
VB_Value
MSB
LSB
FFh
FFh
FFh
FCh
Example 2: Decimal 1 = {0x00h, 0x00h, 0x00h, 0x01h}
VB_Value
MSB
LSB
00h
00h
00h
01h
Value Block Operation Response Format (2 Bytes)
Response
Data Out
Result
SW1
SW2
Value Block Operation Response Codes
Results
SW1 SW2
Meaning
Success
90 00h
The operation is completed successfully.
Error
63 00h
The operation is failed.
5.3.2.2.6. Read Value Block
This command is used for retrieving the value from the value block. It is only valid for value block.
Read Value Block APDU Format (5 Bytes)
Command
Class
INS
P1
P2
Le
Read Value
Block
FFh
B1h
00h
Block
Number
00h
Where:
Block Number (1 Byte): The value block to be accessed.
Read Value Block Response Format (4 + 2 Bytes)
Response
Data Out
Result
Value
{MSB .. LSB}
SW1
SW2
Where:
Value (4 Bytes): The value returned from the card. The value is a signed long integer (4