Ccid commands, Ccid command pipe bulk-out messages, Pc_to_rdr_iccpoweron – ACS ACR1283L User Manual
Page 11

ACR1283L – Reference Manual
Version 1.00
www.acs.com.hk
Page 11 of 55
Offset
Field
Size
Value
Description
32
dwSynchProtocols
4
00000000h ACR1283L does not support
synchronous card.
36
dwMechanical
4
00000000h
ACR1283L does not support
special mechanical
characteristics.
40
dwFeatures
4
00040040h
ACR1283L supports the
following features:
•
Automatic parameters
negotiation made by the
CCID
•
Short and Extended APDU
level exchange with CCID
44
dwMaxCCIDMessageLength
4
0000020Ah
Maximum message length
accepted by ACR1283L is 522
bytes.
48
bClassGetResponse
1
00h
Indicates that the CCID echoes
the class of the APDU.
49
bClassEnvelope
1
00h
Indicates that the CCID echoes
the class of the APDU.
50
wLCDLayout
2
0000h
No LCD.
52
bPINSupport
1
00h
No PIN Verification.
53
bMaxCCIDBusySlots
1
01h
Only one slot can be
simultaneously busy.
5.2. CCID Commands
5.2.1.
CCID Command Pipe Bulk-OUT Messages
ACR1283L shall follow the CCID Bulk-OUT Messages as specified in CCID section 4. In addition, this
specification defines some extended commands for operating additional features. This section lists
the CCID Bulk-OUT Messages to be supported by ACR1283L.
5.2.1.1. PC_to_RDR_IccPowerOn
This command is used to activate the card slot and return ATR from the card.
Offset
Field
Size
Value
Description
0
bMessageType
1
62h
1
dwLength
4
00000000h Size of extra bytes of this message.
2
bSlot
1
Identifies the slot number for this command.
5
bSeq
1
Sequence number for command.
6
bPowerSelect
1
Voltage that is applied to the ICC.
00h = Automatic Voltage Selection
01h = 5 V
02h = 3 V
7
abRFU
2
Reserved for future use.